Auseo Thermostat / Temperature Control Failure

Wine cooler runs continuously and becomes too cold even at higher set temperatures; no error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted NTC temperature sensor, Stuck compressor relay on control board, Miscalibrated thermostat circuit, Shorted wiring harness

How to Fix / Troubleshooting

Safety: Unplug the unit before testing sensors or removing the control board.

Steps:

  • Verify display: Compare the displayed temperature with an accurate thermometer inside the cabinet. If the display is much higher than actual, the sensor may be faulty.
  • Test cabinet sensor: Remove and measure resistance of the cabinet NTC temperature sensor. If it reads near 0 Ω or does not change with temperature, replace it.
  • Inspect control relay: On the main PCB, check the compressor relay for signs of welding or burning. A stuck relay will keep the compressor running.
  • Replace control board: If the sensor is good but the compressor never shuts off, replace the main control board.

Temporary measure: Until repaired, unplug the cooler periodically to prevent overchilling valuable wine.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements