Auseo
Defrost System Failure
Excessive frost or ice buildup on the back interior wall or around the evaporator; cooling gradually worsens.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open defrost heater, Failed defrost sensor, Faulty defrost control on main PCB, Door gasket leaking warm air
How to Fix / Troubleshooting
Safety: Unplug the wine cooler before defrosting or accessing the evaporator.
Steps:
- Manual defrost: Remove all bottles, unplug the unit, and leave the door open until all ice melts. Do not use sharp tools to chip ice.
- Inspect door gasket: Check for gaps or tears that allow moist air in. Replace the door gasket if it does not seal properly.
- Test defrost heater and sensor: After ice is cleared and panels removed, measure resistance of the defrost heater and defrost NTC sensor. Replace any open or shorted components.
- Check control board: If heater and sensor are good, the defrost control circuit on the main PCB may be defective and require replacement.
Note: Regularly ensure the door is fully closed to minimize frost buildup.