Auseo General Cooling Performance Loss

Wine cooler runs but does not get cold enough; temperature stays above setpoint without any error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Weak compressor, Partial refrigerant leak, Non-operational condenser fan motor

How to Fix / Troubleshooting

Safety: Unplug the Auseo wine cooler before cleaning or accessing the rear compartment.

Steps:

  • Check installation: Ensure adequate clearance around the unit and that it is not installed in a very hot room or enclosed cabinet without ventilation.
  • Clean condenser: Remove the rear lower panel and vacuum or brush dust from the condenser coil and fan blades. This is one of the most common causes of poor cooling.
  • Verify condenser fan: Plug the unit back in and confirm that the condenser fan runs whenever the compressor is on. If the fan is not running, replace the condenser fan motor.
  • Monitor compressor: The compressor should run steadily and be warm to the touch, not extremely hot. Short cycling or loud noises may indicate internal failure.
  • Check door seal: Inspect the door gasket for gaps or tears. Replace the door gasket if it does not seal all around.

Important: If the condenser is clean, fans work, and the compressor runs continuously but the cabinet still does not cool, a sealed system issue (refrigerant leak or weak compressor) is likely and requires a licensed technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor