Auseo
No Power / Dead Appliance
Wine cooler will not power on at all; display is blank and no lights or sounds.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown internal fuse on main PCB, Faulty power cord, Open thermal cutoff, Failed main control board power supply
How to Fix / Troubleshooting
Safety: Ensure the outlet is safe and not overloaded. Unplug the cooler before opening any panels.
Steps:
- Check outlet and breaker: Test the outlet with another device and verify the circuit breaker has not tripped.
- Inspect power cord: Look for visible damage. If damaged, replace the power cord assembly with the correct Auseo part.
- Access main PCB: Remove the rear panel and locate the main control board. Look for a small replaceable fuse on the board.
- Test fuse: With a multimeter, check continuity across the fuse. If open, replace with the same rating. If it blows again immediately, there is a deeper fault.
- Replace control board: If the fuse is good but there is still no power, the board’s power supply is likely failed. Replace the main control board / power module.
Warning: Do not bypass fuses or use incorrect ratings; this is a fire hazard.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board Fuse or Power Cord Assembly
Check Price on Amazon
We may earn a commission from links on this page.