LO
Avanti Temperature Display Under-Range / Sensor Calibration Fault

Display shows LO or L0 and interior temperature is much warmer than indicated.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Cabinet thermistor out of calibration, Loose thermistor connection, Control board ADC (analog-to-digital converter) error, Sensor positioned incorrectly in airflow

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal sensors or the control board.

  • Verify actual temperature: Place an accurate thermometer inside the cooler and compare to the displayed temperature. If the display shows LO or an unrealistically low value, suspect the sensor or board.
  • Inspect cabinet thermistor: Locate the interior temperature sensor and ensure it is firmly attached to the wall and not touching the evaporator directly, which can cause false low readings.
  • Check wiring and connector: Follow the thermistor wire to the control board and verify the connector is tight and free of corrosion.
  • Test resistance: With power off, measure thermistor resistance and compare to expected values at the measured cabinet temperature. A sensor reading far out of range indicates a faulty thermistor.
  • Replace thermistor if needed: Install an OEM Avanti cabinet thermistor and route it as originally installed.
  • Control board replacement: If a new sensor does not correct the LO reading, the control board's measurement circuit may be defective and the board will need replacement.