Avanti Cooling Output Not Engaging

Interior fan runs but there is little or no cool air; compressor or Peltier is off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty main control board cooling relay, Open compressor start circuit, Failed Peltier module, Incorrect temperature sensor reading preventing cooling

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing electrical components.

  • Verify setpoint: Ensure the set temperature is below the current cabinet temperature so the unit should be calling for cooling.
  • Listen for compressor or Peltier: If only the fan runs, the cooling device may not be energized.
  • Inspect control board: Remove the control panel or rear cover to access the main board. Look for burnt relay contacts or damaged traces.
  • Check compressor start components or Peltier wiring: Ensure all connectors are secure and wires are intact.
  • Sensor check: A faulty thermistor reading too low can prevent cooling. Test and replace the cabinet thermistor if necessary.
  • Replace failed parts: Install an OEM Avanti main control board, compressor start relay, or Peltier module as indicated by diagnostics.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Peltier Cooling Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements