Avanti Single-Zone Cooling Failure in Dual-Zone System

Upper zone cools but lower zone is warm (dual-zone model).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed lower zone evaporator fan, Blocked airflow duct between zones, Lower zone thermistor failure, Faulty lower zone control relay

How to Fix / Troubleshooting

Safety: Unplug the cooler before accessing interior panels.

  • Compare zones: Verify that the upper zone reaches set temperature while the lower zone remains warm.
  • Check lower zone fan: Listen for airflow in the lower compartment. If silent, remove the lower rear interior panel and inspect the fan.
  • Inspect for obstructions: Ensure vents between zones are not blocked by bottles or shelves.
  • Test lower zone thermistor: Measure resistance and compare to the upper zone sensor at similar temperature. Replace if out of range.
  • Control board / zone relay: If the fan and sensor are good, the lower zone cooling relay or control circuit may be faulty. Replace the zone control board or main board as required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lower Zone Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements