CF
Beko Compressor Failure / Current Fault Detection

CF error code and compressor does not run, or runs only briefly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Locked compressor, Shorted compressor windings, Failed start device, Faulty compressor current sensor on PCB

How to Fix / Troubleshooting

Safety: Unplug the unit. Work on the compressor area only if you understand mains safety. Do not open the sealed system.

  • Listen for sounds: When previously powered, note if the compressor clicked on and off rapidly or made loud humming noises.
  • Inspect start device: Remove the compressor terminal cover and check the start relay and overload for damage. Replace with a Beko-approved start device if suspect.
  • Measure compressor windings: With the compressor disconnected and using a multimeter, measure resistance between the three terminals. All readings should be finite and not shorted to ground. If windings are shorted or open, the compressor is faulty.
  • Professional repair: Compressor replacement and refrigerant handling must be done by a certified refrigeration technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor