Beko
Upper Zone Airflow or Sensor Failure
Lower zone cools but upper zone warm (dual-zone model)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Upper zone fan not running, Blocked upper vents, Faulty upper zone temperature sensor, Control board not energizing upper zone fan
How to Fix / Troubleshooting
Safety: Disconnect power before removing interior panels.
- Check vents: Make sure upper vents are not blocked by bottles or shelves.
- Inspect upper fan: Access the upper zone fan and check for obstructions or ice. Replace the fan motor if it does not run.
- Test upper sensor: Measure resistance of the upper zone NTC sensor and replace if out of spec.
- Control board: If fan and sensor are good but not powered, the main PCB may be faulty and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Upper Zone Evaporator Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements