E7
BODEGA Condenser Fan Motor Fault

Display shows E7 and the condenser fan at the rear of the unit does not run, causing the sides or back to become very hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, Fan blades obstructed by dust or debris, Loose or burnt fan connector, Faulty fan driver on main control board

How to Fix / Troubleshooting

Safety first: Unplug the wine cooler before removing the rear panel. The condenser coil and compressor may be hot.

Steps to diagnose and fix:

  • Access the condenser fan: Remove the rear lower panel to expose the condenser coil and fan assembly.
  • Inspect for blockage: Check for dust buildup, plastic wrap, or other debris blocking the fan blades. Clean thoroughly with a soft brush and vacuum.
  • Spin test: Rotate the fan blades by hand. If they do not spin freely, the motor bearings may be seized and the motor should be replaced.
  • Check wiring: Inspect the fan motor connector and wires for burns, loose pins, or damage. Reseat the connector on the main PCB if accessible.
  • Electrical test: With the unit powered and calling for cooling (only if trained), measure voltage at the fan connector. If correct voltage is present but the fan does not run, replace the fan motor with a compatible BODEGA condenser fan motor.

When to call a professional: If no voltage is present at the fan connector, the main control board may be defective and should be serviced by a professional.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.