BODEGA

BODEGA Wine Coolers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
dE
Display shows dE and the unit beeps, indicating a door error even when the door appears closed.
Door Switch / Door Ajar Detection Fault
E0
Display shows E0 and the wine cooler does not cool or respond to temperature changes.
Main Control Board Communication Fault
E1
Display shows E1 and the temperature reading is inaccurate or dashes appear instead of a temperature.
Upper Compartment Temperature Sensor (NTC) Failure
E2
Display shows E2 and the lower zone temperature is not displayed correctly or flashes.
Lower Compartment Temperature Sensor (NTC) Failure
E3
Display shows E3 and the cabinet temperature fluctuates widely or the compressor runs erratically.
Ambient Temperature Sensor Failure
E4
Display shows E4 and the evaporator fan may not run or the unit ices up excessively.
Evaporator Temperature Sensor / Defrost Sensor Fault
E5
Display shows E5 and the compressor may not start or may shut off quickly.
Compressor Overload or Start Circuit Fault
E6
Display shows E6 and the internal fan does not run or runs intermittently, causing uneven temperatures.
Evaporator Fan Motor Fault
E7
Display shows E7 and the condenser fan at the rear of the unit does not run, causing the sides or back to become very hot.
Condenser Fan Motor Fault
E8
Display shows E8 and the unit fails to maintain set temperature, often running continuously.
Defrost System Failure
E9
Display shows E9 and the interior light or touch controls behave erratically, sometimes not responding.
User Interface / Touch Control Panel Fault
EC
Display shows EC and the unit is not cooling properly or at all.
General Cooling System Error
F1
Display shows F1 and the unit may shut down or fail to start cooling.
High Temperature Protection / Overheat Fault
F2
Display shows F2 and the unit may not respond to temperature adjustments.
Keypad / Button Stuck Fault
H1
Display shows H1 and the temperature reading is extremely high or flashing, even though the interior feels cool.
High Temperature Sensor Reading / Sensor Short
Hi
Display shows Hi and the interior feels warm; the compressor may run continuously.
High Temperature Alarm
L1
Display shows L1 and the door lock or child lock function is engaged, preventing temperature changes.
Control Panel Lock / Child Lock Activated
Lo
Display shows Lo and the temperature cannot be set lower than a certain value, or the unit appears to be in low-temperature protection mode.
Low Temperature Protection / Anti-Freeze Mode
PF
Display shows PF or flashes after a power outage; unit may beep until acknowledged.
Power Failure Notification
Symptom
Buttons on the control panel do not respond or respond intermittently.
Unresponsive Control Panel
Symptom
Chemical or burning plastic smell when the unit is running.
Overheating Electrical Component
Symptom
Clicking noise every few minutes and the compressor does not stay running.
Compressor Short Cycling / Start Failure
Symptom
Condensation or moisture forming on the glass door or around the door frame.
Door Condensation / Gasket Seal Issue
Symptom
Display is blank or very dim, but the unit still cools.
Display Module / Low Voltage to UI
Symptom
Dual-zone wine cooler shows correct temperature in one zone but the other zone is too warm or too cold.
Single-Zone Cooling Failure in Dual-Zone Unit
Symptom
Excessive frost or ice buildup on the back wall or around the evaporator.
Frost Accumulation / Defrost System Issue
Symptom
Interior light does not turn on when the door is opened, but the unit cools normally.
Interior LED Light Circuit Failure
Symptom
Interior light stays on even when the door is closed, causing the cabinet to warm up.
Stuck Door Switch / Light Control Fault
Symptom
Rattling or vibrating noise when the compressor runs; noise reduces when you press on the cabinet.
Cabinet Vibration / Loose Components
Symptom
Strong musty or moldy odor inside the wine cooler.
Interior Odor / Microbial Growth
Symptom
Temperature varies significantly between shelves; top is warmer than bottom or vice versa.
Uneven Temperature Distribution
Symptom
Unit is very warm on the sides or top, but interior temperature is normal.
Condenser Heat Transfer / Normal Warmth vs Overheating
Symptom
Unit trips the household circuit breaker or GFCI when plugged in or shortly after starting.
Electrical Short or Ground Fault
Symptom
Unit will not power on at all; no lights, no display, no cooling.
No Power / Dead Appliance
Symptom
Water pooling at the bottom of the wine cooler or leaking onto the floor.
Drainage System Blockage / Condensate Leak
Symptom
Wine cooler is cooling but makes a loud humming or buzzing noise from the rear.
Noisy Compressor or Condenser Fan
Symptom
Wine cooler not cooling at all; interior is at room temperature and compressor is not running.
No Cooling / Compressor Not Starting
Symptom
Wine cooler not cooling but interior light and display work; compressor is hot to the touch.
Locked or Overheated Compressor
Symptom
Wine cooler runs but does not get cold enough; temperature stays above the setpoint.
Insufficient Cooling / Partial Loss of Refrigeration