F2
BODEGA Keypad / Button Stuck Fault

Display shows F2 and the unit may not respond to temperature adjustments.

Advertisements

Possible Causes

Stuck physical button, Contaminants under keypad, Faulty touch sensor on UI board, Damaged keypad ribbon cable

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

Steps to diagnose and fix:

  • Inspect buttons: Press each button individually and feel for normal travel. If a button feels stuck, gently work it back and forth.
  • Clean around buttons: Use a soft cloth slightly dampened with mild soap solution to clean around the buttons. Do not allow liquid to enter the panel.
  • Access keypad: Remove the trim or screws securing the control panel to access the keypad and ribbon cable.
  • Check ribbon cable: Ensure the cable is fully seated and not damaged. Reseat both ends.
  • Replace keypad/UI board: If F2 persists, replace the BODEGA keypad or touch control board assembly.

When to call a professional: If you are not comfortable disassembling the control panel, contact a technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Keypad / Touch Control Board
Check Price on Amazon

We may earn a commission from links on this page.