E11
Candy Temperature Calibration or Sensor Range Error

E11 error and the display shows incorrect or fluctuating temperatures not matching actual cabinet temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor out of calibration, Poor sensor placement or contact, Firmware calibration error, Faulty main PCB ADC circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or PCB.

  • Verify with a thermometer: Place an accurate thermometer inside the cabinet and compare to the displayed temperature after several hours of stable operation.
  • Check sensor mounting: Ensure the cabinet NTC sensor is properly clipped to the evaporator cover or liner and not touching warm components or exposed to drafts from the door.
  • Inspect wiring: Loose or intermittent connections can cause fluctuating readings. Reseat connectors at both sensor and PCB.
  • Factory reset / calibration: If the model supports it, perform a control reset as per the service or user manual.
  • Replace sensor: If readings remain unstable, replace the "Cabinet NTC temperature sensor".
  • PCB replacement: If a new sensor does not resolve the issue, the analog-to-digital converter on the "Main control board (PCB)" may be faulty and the board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.