Alarm beeping continuously even though temperature seems normal
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: No live electrical work is needed for basic checks; unplug if accessing switches or boards.
Steps:
- Door switch test: Press the door switch manually with the door open. If the alarm stops, adjust or replace the switch.
- Power reset: Unplug the unit for 5–10 minutes to clear any latched alarm state.
- Check sensors: Verify that cabinet temperatures are within normal range using a thermometer. Inspect sensor connections if readings are borderline.
Repair: Replace a faulty door switch or misreading sensor. If the alarm persists with normal temperatures and good components, the main control board may need replacement.
Repair Difficulty
Required Part
We may earn a commission from links on this page.