Cavin

Cavin Wine Coolers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
dF
Display shows dF and cooling pauses periodically while fans may stop
Defrost Mode Indication / Defrost Cycle Active
E0
Display shows E0 and the wine cooler does not respond to temperature adjustments
Main Control Board Communication Fault
E1
E1 error on display and cabinet temperature reading is inaccurate or dashes are shown
Upper Compartment Temperature Sensor Failure
E2
E2 error on display and lower zone temperature is not controlled correctly
Lower Compartment Temperature Sensor Failure
E3
E3 error code and the compressor cycles abnormally or not at all
Ambient Temperature Sensor Fault
E4
E4 error on display and the evaporator fan does not run or runs intermittently
Evaporator Fan Motor Fault
E5
E5 error code and the unit does not cool or cycles off quickly
Defrost Sensor or Defrost Thermostat Fault
E6
E6 error on display and compressor does not start or stops shortly after starting
Compressor Start Protection or Overload Fault
E7
E7 error code and interior lights or display flicker or go out intermittently
Low Voltage or Power Supply Fault
E8
E8 error and the unit is excessively cold or fails to reach set temperature properly
Thermostat Calibration or Sensor Range Error
E9
E9 error code and the unit runs continuously or not at all, with erratic temperature control
EEPROM / Control Memory Error
H1
H1 error and the display shows unusually high temperature readings
High Temperature Alarm – Upper Zone
H2
H2 error and lower zone temperature remains high despite compressor running
High Temperature Alarm – Lower Zone
Hi
Display shows Hi and temperature cannot be set higher or reading seems stuck at high value
Setpoint Upper Limit or Sensor Over-Range
L1
L1 error and interior temperature is too low, bottles feel near-freezing
Low Temperature Alarm – Upper Zone
L2
L2 error and lower zone is over-chilling, with possible ice on bottles
Low Temperature Alarm – Lower Zone
Lo
Display shows Lo and temperature cannot be set lower than a certain point
Setpoint Lower Limit or Sensor Under-Range
Symptom
Alarm beeping continuously even though temperature seems normal
Stuck Alarm Condition or Faulty Door Switch/Sensor
Symptom
Clicking noise from the rear and compressor repeatedly tries to start but fails
Compressor Hard Start / Start Device Failure
Symptom
Condensation or fogging on the glass door
Door Seal or Ambient Humidity Issue
Symptom
Control buttons unresponsive or only some keys work
Touch Control Panel or Keypad Failure
Symptom
Display is blank and unit appears completely dead
No Power / Input Power Failure
Symptom
Door not closing properly or popping open slightly after being shut
Door Alignment or Gasket Deformation
Symptom
Excessive frost or ice buildup on the evaporator and back wall
Defrost System Failure
Symptom
Interior light not working but cooling is normal
LED Light Assembly or Door Switch Failure
Symptom
Interior surfaces feel hot or warmer than expected near the door frame
Door Frame Heater or Condenser Loop Warmth
Symptom
Interior temperature fluctuates widely, causing wine to warm and cool repeatedly
Inaccurate Temperature Control
Symptom
Lower zone cools but upper zone is warm (on dual-zone models)
Upper Zone Airflow or Circuit Failure
Symptom
Strong chemical or burning smell from the rear of the unit
Electrical Overheating or Component Burnout
Symptom
Unit cycles on and off very frequently (short cycling)
Short Cycling of Compressor
Symptom
Unit is making loud humming, rattling, or vibrating noises
Mechanical Vibration or Fan Noise
Symptom
Unit powers on but compressor and fans do not run at all
Main Control Board or Power Supply Failure
Symptom
Unit vibrates or makes noise specifically when the compressor starts or stops
Compressor Mounting or Refrigerant Line Rattle
Symptom
Upper zone cools but lower zone is warm (on dual-zone models)
Lower Zone Airflow or Circuit Failure
Symptom
Water pooling at the bottom of the cabinet or leaking onto the floor
Clogged Defrost Drain or Condensation Management Issue
Symptom
Wine cooler not cooling at all, display lights up but interior remains at room temperature
Compressor or Sealed System Failure
Symptom
Wine cooler runs constantly but only cools slightly, cannot reach set temperature
Partial Refrigerant Loss or Inefficient Condenser
Advertisements