Lo
Cavin Setpoint Lower Limit or Sensor Under-Range

Display shows Lo and temperature cannot be set lower than a certain point

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Temperature already at minimum allowed, Sensor reading below expected range, Control lock or mode limitation, Faulty NTC sensor

How to Fix / Troubleshooting

Safety first: No live electrical work is needed for basic checks; unplug if accessing sensors.

Steps:

  • Understand limits: Many Cavin wine coolers have a minimum set temperature (e.g., 5°C / 41°F). Lo may simply indicate you've reached that limit.
  • Check actual temperature: Use a thermometer to verify the compartment is not excessively cold.
  • Sensor inspection: If the cabinet is warmer than expected but Lo is shown, inspect and test the relevant NTC sensor for under-range readings (very high resistance).

Repair: Replace the affected NTC sensor if it reads out of range for the measured temperature. If the sensor is good, the main control board may be misinterpreting the signal and require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor