Cavin Lower Zone Airflow or Circuit Failure

Upper zone cools but lower zone is warm (on dual-zone models)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed lower evaporator fan, Blocked lower air channel, Separate lower evaporator leak, Faulty lower zone sensor

How to Fix / Troubleshooting

Safety first: Unplug the wine cooler before removing internal panels.

Steps:

  • Check for airflow: With the unit running (before unplugging), feel for airflow at the lower vents. Weak or no airflow suggests a fan or blockage issue.
  • Inspect lower fan: Remove lower shelves and the rear panel to access the lower evaporator and fan. Check for ice, debris, or a seized motor.
  • Sensor check: Verify the lower zone sensor is properly mounted and connected.

Repair: Replace a failed lower evaporator fan motor or damaged sensor. If the lower evaporator remains warm while the upper is cold and the compressor runs, a sealed system issue specific to the lower circuit may exist and requires professional service.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lower Evaporator Fan Motor or Lower Zone NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements