Cavin Short Cycling of Compressor

Unit cycles on and off very frequently (short cycling)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Oversensitive thermostat placement, Faulty temperature sensor, Control board hysteresis too narrow, High ambient temperature near setpoint

How to Fix / Troubleshooting

Safety first: Unplug the unit before moving sensors or accessing the control board.

Steps:

  • Ambient vs setpoint: Ensure the set temperature is not very close to room temperature, which can cause frequent cycling.
  • Sensor placement: Confirm the sensor is not directly in the cold air stream or touching the evaporator, which can cause rapid temperature swings at the sensor.
  • Power reset: Reset the control to clear any software glitches.

Repair: Replace a faulty sensor that responds too quickly or erratically. If short cycling persists, the main control board may need replacement to correct hysteresis behavior.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor or Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.