Lower zone cools but upper zone is warm (on dual-zone models)
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the unit before internal access.
Steps:
- Airflow check: Feel for airflow at upper vents when the compressor is running. Lack of airflow points to a fan or blockage.
- Inspect upper evaporator: Remove upper shelves and inner rear panel to check for ice buildup or a stalled fan.
- Sensor verification: Confirm the upper sensor is intact and properly connected.
Repair: Replace the upper evaporator fan motor or sensor as needed. If the upper evaporator does not frost while the lower does, a sealed system fault in the upper circuit is likely and should be addressed by a technician.