CELLA Single-Zone Cooling Failure in Dual-Zone System

Dual-zone wine cooler: one zone cooling, the other warm

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed zone-specific evaporator fan, Faulty zone temperature sensor, Damper door stuck closed (if shared system), Zone control circuit failure on main board

How to Fix / Troubleshooting

Safety: Unplug the CELLA dual-zone wine cooler before accessing interior panels.

  • Identify affected zone: Determine whether the upper or lower zone is not cooling.
  • Check fan operation: Listen for the evaporator fan in the affected zone when cooling is demanded. If silent, access and test the zone evaporator fan motor and replace if faulty.
  • Test sensor: Check the zone's temperature sensor resistance and replace the zone NTC sensor if out of spec.
  • Damper (if equipped): On models with a shared cooling system and air damper, inspect the damper door for sticking and repair or replace the air damper assembly if jammed.
  • Control board: If hardware is good, the zone control circuit on the main control board may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Zone Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements