E0
Display shows E0 and the wine cooler does not cool, interior fan may or may not run
Cabinet Temperature Sensor Failure
E1
E1 error on display, wine cooler runs but temperature is inaccurate or fluctuates wildly
Evaporator Temperature Sensor Failure
E10
E10 error on display, unit beeps and may shut down cooling
Door Switch or Door Open Detection Fault
E11
E11 error code, compressor cycles rapidly or not at all, temperature unstable
Compressor Overcurrent or Overheat Protection Fault
E12
E12 error on display, unit does not cool even though fans may run
Low Refrigerant or Sealed System Performance Fault
E13
E13 error code, interior light may not work or stays on, door alarm may sound incorrectly
Interior LED Lighting Circuit Fault
E14
E14 error on display, unit may not accept new temperature settings or settings reset randomly
Non-Volatile Memory or Control Board Configuration Fault
E15
E15 error code, unit may be unresponsive or stuck in standby
Low Voltage or Power Supply Fault
E2
E2 error code, compressor and fans may stop, unit may shut down shortly after starting
Defrost Sensor or Defrost Circuit Fault
E3
E3 error on display, compressor does not start or cycles off quickly, interior warms up
Compressor Start/Overload Protection Fault
E4
E4 error code, interior fan may stop, temperature uneven inside cabinet
Evaporator Fan Motor Fault
E5
E5 error on display, compressor and condenser fan may not run, unit remains warm
Condenser Fan Motor or High Temperature Protection Fault
E6
E6 error code, display may flash, unit may not respond to temperature changes
User Interface / Display Board Communication Fault
E7
E7 error on display, dual-zone models show incorrect temperature in one zone
Upper Zone Temperature Sensor Fault (Dual-Zone Models)
E8
E8 error on display, lower zone temperature not controlled correctly on dual-zone models
Lower Zone Temperature Sensor Fault (Dual-Zone Models)
E9
E9 error code, compressor may run continuously or not at all, temperature drifts
Ambient Temperature Sensor Fault
Symptom
Buttons on the control panel unresponsive or respond intermittently
User Interface Keypad Failure
Symptom
Chemical or burning smell when the unit is running
Electrical Overheating or Component Failure
Symptom
Clicking sound and compressor tries to start but shuts off repeatedly
Compressor Hard Start / Overload Trip
Symptom
Condensation or moisture on the inside of the glass door
High Humidity or Door Seal Issue
Symptom
Display is blank or very dim, but cooling still works
Display Backlight or UI Power Issue
Symptom
Door alarm beeping even though the door appears closed
False Door Open Detection
Symptom
Door not sealing properly, warm air entering cabinet
Door Gasket or Hinge Alignment Problem
Symptom
Dual-zone wine cooler: one zone cooling, the other warm
Single-Zone Cooling Failure in Dual-Zone System
Symptom
Excessive frost or ice buildup on the back wall or evaporator
Defrost System Failure or Air Infiltration
Symptom
Exterior of the wine cooler cabinet feels very hot, especially near sides or front frame
Condenser Heat Dissipation / Ventilation Issue
Symptom
High-pitched squealing or chirping noise from inside the cabinet
Evaporator Fan Motor Noise
Symptom
Interior light not working but cooler otherwise operates normally
Interior Lighting Failure
Symptom
Interior light stays on even when the door is closed
Door Switch Stuck or Misaligned
Symptom
Loud humming or buzzing noise from the back of the wine cooler
Compressor or Condenser Fan Noise
Symptom
Rattling or vibrating noise, especially when compressor starts or stops
Cabinet Vibration / Loose Components
Symptom
Shelves difficult to slide or do not sit level
Shelf Support or Rail Misalignment
Symptom
Strong musty or moldy odor inside the wine cooler
Microbial Growth / Poor Air Circulation
Symptom
Unit cycles on and off very frequently (short cycling)
Improper Cycling / Control Issue
Symptom
Unit makes gurgling or hissing noises periodically
Normal Refrigerant Flow Sounds
Symptom
Water pooling at the bottom of the wine cooler or on the floor in front
Drainage Blockage or Condensate Management Failure
Symptom
Wine cooler interior too cold, bottles freezing near the back
Overcooling / Thermostat Control Failure
Symptom
Wine cooler not cooling at all, display is on but interior remains at room temperature
Compressor or Cooling System Not Operating
Symptom
Wine cooler not turning on at all, no lights or display
No Power / Dead Unit
Symptom
Wine cooler runs continuously but does not reach set temperature (insufficient cooling)
Reduced Cooling Capacity / Sealed System Inefficiency
Symptom
Wine cooler temperature display inaccurate compared to a thermometer inside
Temperature Calibration / Sensor Drift
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E0 |
Display shows E0 and the wine cooler does not cool, interior fan may or may not run
|
Cabinet Temperature Sensor Failure | View Details |
| E1 |
E1 error on display, wine cooler runs but temperature is inaccurate or fluctuates wildly
|
Evaporator Temperature Sensor Failure | View Details |
| E10 |
E10 error on display, unit beeps and may shut down cooling
|
Door Switch or Door Open Detection Fault | View Details |
| E11 |
E11 error code, compressor cycles rapidly or not at all, temperature unstable
|
Compressor Overcurrent or Overheat Protection Fault | View Details |
| E12 |
E12 error on display, unit does not cool even though fans may run
|
Low Refrigerant or Sealed System Performance Fault | View Details |
| E13 |
E13 error code, interior light may not work or stays on, door alarm may sound incorrectly
|
Interior LED Lighting Circuit Fault | View Details |
| E14 |
E14 error on display, unit may not accept new temperature settings or settings reset randomly
|
Non-Volatile Memory or Control Board Configuration Fault | View Details |
| E15 |
E15 error code, unit may be unresponsive or stuck in standby
|
Low Voltage or Power Supply Fault | View Details |
| E2 |
E2 error code, compressor and fans may stop, unit may shut down shortly after starting
|
Defrost Sensor or Defrost Circuit Fault | View Details |
| E3 |
E3 error on display, compressor does not start or cycles off quickly, interior warms up
|
Compressor Start/Overload Protection Fault | View Details |
| E4 |
E4 error code, interior fan may stop, temperature uneven inside cabinet
|
Evaporator Fan Motor Fault | View Details |
| E5 |
E5 error on display, compressor and condenser fan may not run, unit remains warm
|
Condenser Fan Motor or High Temperature Protection Fault | View Details |
| E6 |
E6 error code, display may flash, unit may not respond to temperature changes
|
User Interface / Display Board Communication Fault | View Details |
| E7 |
E7 error on display, dual-zone models show incorrect temperature in one zone
|
Upper Zone Temperature Sensor Fault (Dual-Zone Models) | View Details |
| E8 |
E8 error on display, lower zone temperature not controlled correctly on dual-zone models
|
Lower Zone Temperature Sensor Fault (Dual-Zone Models) | View Details |
| E9 |
E9 error code, compressor may run continuously or not at all, temperature drifts
|
Ambient Temperature Sensor Fault | View Details |
| – |
Buttons on the control panel unresponsive or respond intermittently
|
User Interface Keypad Failure | View Details |
| – |
Chemical or burning smell when the unit is running
|
Electrical Overheating or Component Failure | View Details |
| – |
Clicking sound and compressor tries to start but shuts off repeatedly
|
Compressor Hard Start / Overload Trip | View Details |
| – |
Condensation or moisture on the inside of the glass door
|
High Humidity or Door Seal Issue | View Details |
| – |
Display is blank or very dim, but cooling still works
|
Display Backlight or UI Power Issue | View Details |
| – |
Door alarm beeping even though the door appears closed
|
False Door Open Detection | View Details |
| – |
Door not sealing properly, warm air entering cabinet
|
Door Gasket or Hinge Alignment Problem | View Details |
| – |
Dual-zone wine cooler: one zone cooling, the other warm
|
Single-Zone Cooling Failure in Dual-Zone System | View Details |
| – |
Excessive frost or ice buildup on the back wall or evaporator
|
Defrost System Failure or Air Infiltration | View Details |
| – |
Exterior of the wine cooler cabinet feels very hot, especially near sides or front frame
|
Condenser Heat Dissipation / Ventilation Issue | View Details |
| – |
High-pitched squealing or chirping noise from inside the cabinet
|
Evaporator Fan Motor Noise | View Details |
| – |
Interior light not working but cooler otherwise operates normally
|
Interior Lighting Failure | View Details |
| – |
Interior light stays on even when the door is closed
|
Door Switch Stuck or Misaligned | View Details |
| – |
Loud humming or buzzing noise from the back of the wine cooler
|
Compressor or Condenser Fan Noise | View Details |
| – |
Rattling or vibrating noise, especially when compressor starts or stops
|
Cabinet Vibration / Loose Components | View Details |
| – |
Shelves difficult to slide or do not sit level
|
Shelf Support or Rail Misalignment | View Details |
| – |
Strong musty or moldy odor inside the wine cooler
|
Microbial Growth / Poor Air Circulation | View Details |
| – |
Unit cycles on and off very frequently (short cycling)
|
Improper Cycling / Control Issue | View Details |
| – |
Unit makes gurgling or hissing noises periodically
|
Normal Refrigerant Flow Sounds | View Details |
| – |
Water pooling at the bottom of the wine cooler or on the floor in front
|
Drainage Blockage or Condensate Management Failure | View Details |
| – |
Wine cooler interior too cold, bottles freezing near the back
|
Overcooling / Thermostat Control Failure | View Details |
| – |
Wine cooler not cooling at all, display is on but interior remains at room temperature
|
Compressor or Cooling System Not Operating | View Details |
| – |
Wine cooler not turning on at all, no lights or display
|
No Power / Dead Unit | View Details |
| – |
Wine cooler runs continuously but does not reach set temperature (insufficient cooling)
|
Reduced Cooling Capacity / Sealed System Inefficiency | View Details |
| – |
Wine cooler temperature display inaccurate compared to a thermometer inside
|
Temperature Calibration / Sensor Drift | View Details |
No matching codes found