CELLA

CELLA Wine Coolers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
Display shows E0 and the wine cooler does not cool, interior fan may or may not run
Cabinet Temperature Sensor Failure
E1
E1 error on display, wine cooler runs but temperature is inaccurate or fluctuates wildly
Evaporator Temperature Sensor Failure
E10
E10 error on display, unit beeps and may shut down cooling
Door Switch or Door Open Detection Fault
E11
E11 error code, compressor cycles rapidly or not at all, temperature unstable
Compressor Overcurrent or Overheat Protection Fault
E12
E12 error on display, unit does not cool even though fans may run
Low Refrigerant or Sealed System Performance Fault
E13
E13 error code, interior light may not work or stays on, door alarm may sound incorrectly
Interior LED Lighting Circuit Fault
E14
E14 error on display, unit may not accept new temperature settings or settings reset randomly
Non-Volatile Memory or Control Board Configuration Fault
E15
E15 error code, unit may be unresponsive or stuck in standby
Low Voltage or Power Supply Fault
E2
E2 error code, compressor and fans may stop, unit may shut down shortly after starting
Defrost Sensor or Defrost Circuit Fault
E3
E3 error on display, compressor does not start or cycles off quickly, interior warms up
Compressor Start/Overload Protection Fault
E4
E4 error code, interior fan may stop, temperature uneven inside cabinet
Evaporator Fan Motor Fault
E5
E5 error on display, compressor and condenser fan may not run, unit remains warm
Condenser Fan Motor or High Temperature Protection Fault
E6
E6 error code, display may flash, unit may not respond to temperature changes
User Interface / Display Board Communication Fault
E7
E7 error on display, dual-zone models show incorrect temperature in one zone
Upper Zone Temperature Sensor Fault (Dual-Zone Models)
E8
E8 error on display, lower zone temperature not controlled correctly on dual-zone models
Lower Zone Temperature Sensor Fault (Dual-Zone Models)
E9
E9 error code, compressor may run continuously or not at all, temperature drifts
Ambient Temperature Sensor Fault
Symptom
Buttons on the control panel unresponsive or respond intermittently
User Interface Keypad Failure
Symptom
Chemical or burning smell when the unit is running
Electrical Overheating or Component Failure
Symptom
Clicking sound and compressor tries to start but shuts off repeatedly
Compressor Hard Start / Overload Trip
Symptom
Condensation or moisture on the inside of the glass door
High Humidity or Door Seal Issue
Symptom
Display is blank or very dim, but cooling still works
Display Backlight or UI Power Issue
Symptom
Door alarm beeping even though the door appears closed
False Door Open Detection
Symptom
Door not sealing properly, warm air entering cabinet
Door Gasket or Hinge Alignment Problem
Symptom
Dual-zone wine cooler: one zone cooling, the other warm
Single-Zone Cooling Failure in Dual-Zone System
Symptom
Excessive frost or ice buildup on the back wall or evaporator
Defrost System Failure or Air Infiltration
Symptom
Exterior of the wine cooler cabinet feels very hot, especially near sides or front frame
Condenser Heat Dissipation / Ventilation Issue
Symptom
High-pitched squealing or chirping noise from inside the cabinet
Evaporator Fan Motor Noise
Symptom
Interior light not working but cooler otherwise operates normally
Interior Lighting Failure
Symptom
Interior light stays on even when the door is closed
Door Switch Stuck or Misaligned
Symptom
Loud humming or buzzing noise from the back of the wine cooler
Compressor or Condenser Fan Noise
Symptom
Rattling or vibrating noise, especially when compressor starts or stops
Cabinet Vibration / Loose Components
Symptom
Shelves difficult to slide or do not sit level
Shelf Support or Rail Misalignment
Symptom
Strong musty or moldy odor inside the wine cooler
Microbial Growth / Poor Air Circulation
Symptom
Unit cycles on and off very frequently (short cycling)
Improper Cycling / Control Issue
Symptom
Unit makes gurgling or hissing noises periodically
Normal Refrigerant Flow Sounds
Symptom
Water pooling at the bottom of the wine cooler or on the floor in front
Drainage Blockage or Condensate Management Failure
Symptom
Wine cooler interior too cold, bottles freezing near the back
Overcooling / Thermostat Control Failure
Symptom
Wine cooler not cooling at all, display is on but interior remains at room temperature
Compressor or Cooling System Not Operating
Symptom
Wine cooler not turning on at all, no lights or display
No Power / Dead Unit
Symptom
Wine cooler runs continuously but does not reach set temperature (insufficient cooling)
Reduced Cooling Capacity / Sealed System Inefficiency
Symptom
Wine cooler temperature display inaccurate compared to a thermometer inside
Temperature Calibration / Sensor Drift
Advertisements