CELLA Reduced Cooling Capacity / Sealed System Inefficiency

Wine cooler runs continuously but does not reach set temperature (insufficient cooling)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Weak compressor, Partial refrigerant leak, Restricted capillary tube

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning or inspecting the rear components.

  • Clean condenser: Remove the rear lower panel and thoroughly clean the condenser coil with a brush and vacuum. Ensure the condenser fan is running and unobstructed.
  • Check door gasket: Inspect the door gasket for gaps or tears that allow warm air in. Replace the CELLA door gasket if it does not seal all around.
  • Verify ambient conditions: Ensure the wine cooler is not installed in a very hot environment or in direct sunlight, which can reduce performance.
  • Observe frost pattern: Remove the interior rear panel and check the evaporator after 15–20 minutes of operation. A partial frost pattern or only a small section frosted suggests a sealed system problem that requires a professional technician to diagnose and repair.
Advertisements

Repair Difficulty

Professional Required 5/5