E11
CELLA
Compressor Overcurrent or Overheat Protection Fault
E11 error code, compressor cycles rapidly or not at all, temperature unstable
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser airflow, Failed condenser fan, High ambient temperature around unit, Faulty compressor thermal protector or current sensor on main PCB
How to Fix / Troubleshooting
Safety: Unplug the unit and allow the compressor to cool before touching it.
- Check installation: Ensure there is adequate clearance around the CELLA wine cooler (typically at least several centimeters on sides and back) for ventilation.
- Clean condenser: Remove rear lower panel and clean the condenser coil thoroughly with a brush and vacuum.
- Verify condenser fan: Confirm the condenser fan motor runs whenever the compressor is on. Replace if not operating.
- Inspect compressor temperature: If the compressor is extremely hot to the touch, the thermal protector may be tripping. Allow it to cool and see if E11 clears after cleaning and improving airflow.
- Control board sensor: If airflow is good and the compressor is not overheating but E11 persists, the current/temperature sensing circuit on the main control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.