EdgeStar
Door Alignment / Hinge or Gasket Issue
Door does not close properly or pops open slightly after being shut.
Advertisements
Possible Causes
Misaligned door hinges, Warped door gasket, Unit not level, Shelves or bottles interfering with door
How to Fix / Troubleshooting
Safety: Unplug the unit before adjusting hinges to avoid accidental fan or compressor operation while working.
Steps:
- Check for obstructions: Ensure no bottles or shelves protrude and contact the door.
- Level the unit: Adjust leveling legs so the cooler is slightly tilted back, helping the door close and seal.
- Inspect hinges: Check that hinge screws are tight and that the door is not sagging. Loosen screws slightly, adjust the door position, and retighten.
- Examine gasket: Look for twisted, torn, or hardened sections of the door gasket. Warm the gasket gently with a hair dryer and reshape if slightly deformed.
- Replace gasket if needed: If the gasket is damaged or will not seal, install a new EdgeStar-compatible door gasket.
Test: Close the door on a strip of paper at various points; you should feel resistance when pulling it out.
Advertisements
Repair Difficulty
Easy
2/5