dF
Display alternates to show dF and the unit may pause cooling periodically.
Defrost Mode Indication / Defrost Cycle Active
E0
Display shows E0 and the wine cooler is not cooling or only slightly cools.
Cabinet Temperature Sensor (Thermistor) Failure
E1
Display shows E1 and the wine cooler does not maintain the set temperature or cycles erratically.
Evaporator Temperature Sensor Failure
E2
Display shows E2 and the wine cooler may run continuously or shut down prematurely.
Ambient (Room) Temperature Sensor Failure
E3
Display shows E3 and the compressor may not start or may short-cycle.
Compressor Start/Overload Protection Fault (Control Board Sensing Error)
E4
Display shows E4 and the unit may have heavy frost buildup or poor cooling performance.
Defrost Sensor or Defrost Circuit Failure
E5
Display shows E5 and the wine cooler may shut down or run erratically, sometimes with beeping.
Control Panel / Keypad Communication Error
E6
Display shows E6 and the interior fan may not run, or the unit may overcool or have uneven temperatures.
Evaporator Fan Feedback / Fan Circuit Error
E7
Display shows E7 and the unit may not respond properly to temperature settings or may shut down unexpectedly.
EEPROM / Control Board Memory Error
E8
Display shows E8 and the compressor may not run, or the unit may stay off despite correct settings.
High Temperature Protection / Overheat Error
E9
Display shows E9 and the unit may not cool properly, sometimes accompanied by unusual compressor cycling.
Low Temperature / Freeze Protection Error
ER
Display shows ER or flashes all segments and the unit is unresponsive to button presses.
General Control Error / Firmware Fault
H1
Display shows H1 and the interior temperature reading is abnormally high, often with the compressor running continuously.
High Temperature Alarm Condition
Hi
Display shows Hi for temperature and the unit may not cool or may be very warm inside.
High Temperature Display Over-Range
L1
Display shows L1 and the interior temperature reading is abnormally low, sometimes with bottles near the back freezing.
Low Temperature Alarm Condition
Lo
Display shows Lo for temperature and will not allow setting below a certain point.
Low Temperature Setpoint Limit / Display Under-Range
Symptom
Burning smell or electrical odor coming from the wine cooler.
Overheating Electrical Component
Symptom
Clicking or ticking noise from the compressor area; compressor repeatedly tries to start and stops.
Compressor Hard Start / Overload Cycling
Symptom
Condensation forming on the glass door or around the door frame.
Door Condensation / Thermal Bridge
Symptom
Display works but buttons do not respond or respond intermittently.
Unresponsive Touchpad / Keypad Failure
Symptom
Door does not close properly or pops open slightly after being shut.
Door Alignment / Hinge or Gasket Issue
Symptom
Dual-zone wine cooler shows large temperature difference between zones or zones are reversed (upper colder than lower, etc.).
Dual-Zone Airflow or Sensor Misconfiguration
Symptom
Excessive frost or ice buildup on the back wall or around the evaporator.
Frost Accumulation / Defrost System Issue
Symptom
Glass door appears foggy or has condensation between the glass panes.
Failed Door Glass Seal / Insulated Glass Unit Leak
Symptom
High-pitched squealing or grinding noise from inside the cabinet.
Evaporator Fan Motor Bearing Failure
Symptom
Interior light does not turn on when the door is opened, but cooling works normally.
Interior LED Lighting Failure
Symptom
Interior temperature fluctuates widely; some bottles too warm while others are too cold.
Poor Air Circulation / Temperature Stratification
Symptom
Strong musty or moldy odor inside the wine cooler.
Microbial Growth / Odor Contamination
Symptom
Temperature display is inaccurate compared to a separate thermometer inside the cabinet.
Temperature Calibration / Sensor Drift
Symptom
Unit cycles on and off very frequently (short cycling), even when temperature is stable.
Short Cycling / Control Hysteresis Issue
Symptom
Unit emits a loud buzzing or humming noise from the back that is louder than normal compressor operation.
Noisy Condenser Fan or Vibrating Condenser Coil
Symptom
Unit makes loud rattling or vibrating noises during operation.
Excessive Vibration / Loose Components
Symptom
Unit runs continuously and rarely shuts off, but interior temperature is acceptable.
Extended Run Time / Inefficient Operation
Symptom
Unit trips the circuit breaker or GFCI outlet when it starts.
Electrical Short or Ground Fault
Symptom
Water pooling at the bottom of the cabinet or leaking onto the floor in front of the wine cooler.
Drainage / Condensate Leak
Symptom
Wine cooler does not power on at all; display is blank and no lights or fans run.
No Power / Dead Unit
Symptom
Wine cooler not cooling at all; interior at room temperature, display powered.
Compressor Not Running
Symptom
Wine cooler runs but does not get cold enough; interior stays above 60°F even after many hours.
Loss of Cooling Capacity / Sealed System Underperformance
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| dF |
Display alternates to show dF and the unit may pause cooling periodically.
|
Defrost Mode Indication / Defrost Cycle Active | View Details |
| E0 |
Display shows E0 and the wine cooler is not cooling or only slightly cools.
|
Cabinet Temperature Sensor (Thermistor) Failure | View Details |
| E1 |
Display shows E1 and the wine cooler does not maintain the set temperature or cycles erratically.
|
Evaporator Temperature Sensor Failure | View Details |
| E2 |
Display shows E2 and the wine cooler may run continuously or shut down prematurely.
|
Ambient (Room) Temperature Sensor Failure | View Details |
| E3 |
Display shows E3 and the compressor may not start or may short-cycle.
|
Compressor Start/Overload Protection Fault (Control Board Sensing Error) | View Details |
| E4 |
Display shows E4 and the unit may have heavy frost buildup or poor cooling performance.
|
Defrost Sensor or Defrost Circuit Failure | View Details |
| E5 |
Display shows E5 and the wine cooler may shut down or run erratically, sometimes with beeping.
|
Control Panel / Keypad Communication Error | View Details |
| E6 |
Display shows E6 and the interior fan may not run, or the unit may overcool or have uneven temperatures.
|
Evaporator Fan Feedback / Fan Circuit Error | View Details |
| E7 |
Display shows E7 and the unit may not respond properly to temperature settings or may shut down unexpectedly.
|
EEPROM / Control Board Memory Error | View Details |
| E8 |
Display shows E8 and the compressor may not run, or the unit may stay off despite correct settings.
|
High Temperature Protection / Overheat Error | View Details |
| E9 |
Display shows E9 and the unit may not cool properly, sometimes accompanied by unusual compressor cycling.
|
Low Temperature / Freeze Protection Error | View Details |
| ER |
Display shows ER or flashes all segments and the unit is unresponsive to button presses.
|
General Control Error / Firmware Fault | View Details |
| H1 |
Display shows H1 and the interior temperature reading is abnormally high, often with the compressor running continuously.
|
High Temperature Alarm Condition | View Details |
| Hi |
Display shows Hi for temperature and the unit may not cool or may be very warm inside.
|
High Temperature Display Over-Range | View Details |
| L1 |
Display shows L1 and the interior temperature reading is abnormally low, sometimes with bottles near the back freezing.
|
Low Temperature Alarm Condition | View Details |
| Lo |
Display shows Lo for temperature and will not allow setting below a certain point.
|
Low Temperature Setpoint Limit / Display Under-Range | View Details |
| – |
Burning smell or electrical odor coming from the wine cooler.
|
Overheating Electrical Component | View Details |
| – |
Clicking or ticking noise from the compressor area; compressor repeatedly tries to start and stops.
|
Compressor Hard Start / Overload Cycling | View Details |
| – |
Condensation forming on the glass door or around the door frame.
|
Door Condensation / Thermal Bridge | View Details |
| – |
Display works but buttons do not respond or respond intermittently.
|
Unresponsive Touchpad / Keypad Failure | View Details |
| – |
Door does not close properly or pops open slightly after being shut.
|
Door Alignment / Hinge or Gasket Issue | View Details |
| – |
Dual-zone wine cooler shows large temperature difference between zones or zones are reversed (upper colder than lower, etc.).
|
Dual-Zone Airflow or Sensor Misconfiguration | View Details |
| – |
Excessive frost or ice buildup on the back wall or around the evaporator.
|
Frost Accumulation / Defrost System Issue | View Details |
| – |
Glass door appears foggy or has condensation between the glass panes.
|
Failed Door Glass Seal / Insulated Glass Unit Leak | View Details |
| – |
High-pitched squealing or grinding noise from inside the cabinet.
|
Evaporator Fan Motor Bearing Failure | View Details |
| – |
Interior light does not turn on when the door is opened, but cooling works normally.
|
Interior LED Lighting Failure | View Details |
| – |
Interior temperature fluctuates widely; some bottles too warm while others are too cold.
|
Poor Air Circulation / Temperature Stratification | View Details |
| – |
Strong musty or moldy odor inside the wine cooler.
|
Microbial Growth / Odor Contamination | View Details |
| – |
Temperature display is inaccurate compared to a separate thermometer inside the cabinet.
|
Temperature Calibration / Sensor Drift | View Details |
| – |
Unit cycles on and off very frequently (short cycling), even when temperature is stable.
|
Short Cycling / Control Hysteresis Issue | View Details |
| – |
Unit emits a loud buzzing or humming noise from the back that is louder than normal compressor operation.
|
Noisy Condenser Fan or Vibrating Condenser Coil | View Details |
| – |
Unit makes loud rattling or vibrating noises during operation.
|
Excessive Vibration / Loose Components | View Details |
| – |
Unit runs continuously and rarely shuts off, but interior temperature is acceptable.
|
Extended Run Time / Inefficient Operation | View Details |
| – |
Unit trips the circuit breaker or GFCI outlet when it starts.
|
Electrical Short or Ground Fault | View Details |
| – |
Water pooling at the bottom of the cabinet or leaking onto the floor in front of the wine cooler.
|
Drainage / Condensate Leak | View Details |
| – |
Wine cooler does not power on at all; display is blank and no lights or fans run.
|
No Power / Dead Unit | View Details |
| – |
Wine cooler not cooling at all; interior at room temperature, display powered.
|
Compressor Not Running | View Details |
| – |
Wine cooler runs but does not get cold enough; interior stays above 60°F even after many hours.
|
Loss of Cooling Capacity / Sealed System Underperformance | View Details |
No matching codes found
Advertisements