Display shows E0 and the wine cooler is not cooling or only slightly cools.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the wine cooler from the wall outlet before removing any panels or handling wiring. Do not work on the unit while it is energized.
Steps to check and address E0:
- Power reset: Unplug the unit for 5 minutes, then plug it back in to see if the code clears. If E0 returns, continue.
- Locate the cabinet thermistor: On most EdgeStar wine coolers, the cabinet temperature sensor is a small probe or bullet-style sensor mounted on the interior liner (often behind a small plastic cover or routed through the rear wall into the evaporator area).
- Inspect the sensor and wiring: Remove the interior shelves as needed. Look for a small plastic cover or grommet where the sensor enters the liner. Check for cuts, pinched wires, corrosion at the connector, or a sensor that has pulled out of its clip.
- Check the connector at the control board: Access the control board (usually behind the upper front control panel or rear service panel). Verify the thermistor plug is fully seated and not corroded or burnt.
- Test the thermistor (if you have a multimeter): With the unit unplugged, disconnect the thermistor from the board and measure resistance across the two leads. Compare to a typical NTC curve (for many EdgeStar sensors, ~10kΩ at 77°F/25°C). If it reads open (OL), shorted (near 0Ω), or wildly off, the sensor is bad.
- Replace the thermistor if faulty: Order a compatible EdgeStar cabinet temperature sensor/thermistor for your model. Route the new sensor along the same path as the old one, secure it in the clip or bracket, and reconnect to the control board.
- If the sensor tests good: The issue may be with the control board’s sensor input circuit. Inspect the board for burnt components or corrosion. If present, replace the main control board.
When to stop: If you are not comfortable testing resistance or accessing the control board, contact a qualified appliance technician.