EdgeStar Extended Run Time / Inefficient Operation

Unit runs continuously and rarely shuts off, but interior temperature is acceptable.

Advertisements

Possible Causes

Door gasket leakage, Dirty condenser coil, High ambient temperature, Poor insulation or door glass seal degradation

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning or gasket replacement.

Steps:

  • Clean condenser coil: Remove dust and debris to improve efficiency.
  • Inspect door gasket: Check for gaps or tears and replace if necessary.
  • Check installation: Ensure adequate ventilation and that the unit is not installed in direct sunlight or near heat sources.
  • Monitor duty cycle: After cleaning and gasket repair, observe whether the compressor begins to cycle off more frequently.

Note: In very warm rooms, longer run times are normal, but the compressor should still cycle off periodically.