GE Profile No Power / Dead Unit

Unit does not power on at all, no lights or display

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker or blown fuse, Faulty power cord, Failed main control board power supply, Loose internal power connections

How to Fix / Troubleshooting

Safety: Always disconnect from power before opening panels. If you are not comfortable working with line voltage, contact a technician.

  • Check house power: Verify the circuit breaker is not tripped and the outlet has power by plugging in another device.
  • Inspect power cord: Look for cuts, burns, or loose plug blades. Replace the cord if damaged.
  • Internal connections: Remove the rear panel and check that the power cord connections to the main control board or terminal block are tight.
  • Board inspection: Look for burnt components or blown fuses on the main control board. Some boards have a replaceable fuse; replace only with the same rating.
  • Replace main control board: If power is present at the board input but the unit remains dead, replace the main control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon