GE Profile Wine Coolers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
CF
Display shows CF and unit may not cool or respond properly
Communication Failure Between Control Boards
dO
Display shows dO or DO and an audible alarm sounds, door icon may flash
Door Open / Door Switch Fault
E1
Digital display shows E1 and cabinet temperature is warmer than the set temperature
Cabinet Temperature Sensor (Thermistor) Fault
E2
Display shows E2 and unit may overcool or not cool properly
Evaporator Temperature Sensor Fault
E3
Display shows E3 and temperature control is erratic or unresponsive
Ambient (Room) Temperature Sensor Fault
E4
Display shows E4 and compressor or fans may not run correctly
Defrost Sensor / Defrost Circuit Fault
E5
Display shows E5 and unit may shut down or fail to cool properly
Compressor Overload / High Temperature Protection Fault
E6
Display shows E6 and temperature set buttons may not respond correctly
User Interface / Keypad Communication Fault
E7
Display shows E7 and interior lights or fans may behave erratically
Low Voltage / Power Supply Fault
E8
Display shows E8 and the unit may not maintain separate temperatures in dual‑zone models
Dual‑Zone Communication / Divider Sensor Fault
E9
Display shows E9 and compressor or fans may not start
Compressor Relay / Driver Fault
F1
Display shows F1 and unit may shut down or run erratically
General Control Board Fault
F2
Display shows F2 and interior light or fan may not operate correctly
Fan or Light Output Fault
F3
Display shows F3 and temperature readings are obviously incorrect
Temperature Calibration / Sensor Range Fault
H1
Display shows H1 and interior temperature is very warm
High Temperature Alarm Condition
L1
Display shows L1 and interior temperature is very cold, bottles may be frosting
Low Temperature Alarm Condition
LC
Display shows LC and controls are locked, buttons do not respond
Control Lock (Child Lock) Active
Symptom
Buttons on the control panel do not respond or respond intermittently
Keypad / Touch Control Failure
Symptom
Cabinet or door exterior feels hot to the touch
High Cabinet Surface Temperature
Symptom
Chemical or plastic smell from new or recently installed wine cooler
New Appliance Odor / Off‑gassing
Symptom
Clicking sound from compressor area, compressor tries to start then stops repeatedly
Compressor Hard Start / Short Cycling
Symptom
Compressor and fans run continuously, unit rarely cycles off
Continuous Run / Overcooling Attempt
Symptom
Condensation or moisture forming on the inside of the glass door
Door Condensation / High Humidity
Symptom
Condensation or water droplets forming on interior walls and shelves
Interior Condensation
Symptom
Display is blank or very dim, but unit still cools
Display / User Interface Failure
Symptom
Door does not close properly or pops open, temperature fluctuates
Door Alignment / Gasket Failure
Symptom
Excessive frost or ice buildup on interior back wall or evaporator cover
Frost Buildup / Defrost System Failure
Symptom
Interior light does not turn on when door is opened
Interior Light Failure
Symptom
Interior light stays on even when the door is closed, cabinet may get warm
Light Stuck On / Door Switch Fault
Symptom
Loud humming, buzzing, or rattling noise during operation
Excessive Noise / Vibration
Symptom
Lower zone cools but upper zone is warm (dual‑zone model)
Upper Zone Cooling Failure (Dual‑Zone)
Symptom
Strong musty or moldy odor inside the wine cooler
Odor / Biological Growth
Symptom
Temperature fluctuates widely, wines too warm at times and too cold at others
Temperature Instability
Symptom
Unit cycles on and off very frequently, short run times
Short Cycling
Symptom
Unit does not power on at all, no lights or display
No Power / Dead Unit
Symptom
Unit trips the household circuit breaker or GFCI outlet
Electrical Short / Ground Fault
Symptom
Upper zone cools but lower zone is warm (dual‑zone model)
Single Zone Cooling Failure (Dual‑Zone)
Symptom
Water pooling at the bottom of the cabinet or leaking onto the floor
Drainage / Condensate Leak
Symptom
Wine cooler not cooling at all, interior at room temperature, display may still light
No Cooling / Compressor Not Running
Symptom
Wine cooler runs but does not get cold enough, temperature stays above setpoint
Insufficient Cooling / Warm Cabinet
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| CF |
Display shows CF and unit may not cool or respond properly
|
Communication Failure Between Control Boards | View Details |
| dO |
Display shows dO or DO and an audible alarm sounds, door icon may flash
|
Door Open / Door Switch Fault | View Details |
| E1 |
Digital display shows E1 and cabinet temperature is warmer than the set temperature
|
Cabinet Temperature Sensor (Thermistor) Fault | View Details |
| E2 |
Display shows E2 and unit may overcool or not cool properly
|
Evaporator Temperature Sensor Fault | View Details |
| E3 |
Display shows E3 and temperature control is erratic or unresponsive
|
Ambient (Room) Temperature Sensor Fault | View Details |
| E4 |
Display shows E4 and compressor or fans may not run correctly
|
Defrost Sensor / Defrost Circuit Fault | View Details |
| E5 |
Display shows E5 and unit may shut down or fail to cool properly
|
Compressor Overload / High Temperature Protection Fault | View Details |
| E6 |
Display shows E6 and temperature set buttons may not respond correctly
|
User Interface / Keypad Communication Fault | View Details |
| E7 |
Display shows E7 and interior lights or fans may behave erratically
|
Low Voltage / Power Supply Fault | View Details |
| E8 |
Display shows E8 and the unit may not maintain separate temperatures in dual‑zone models
|
Dual‑Zone Communication / Divider Sensor Fault | View Details |
| E9 |
Display shows E9 and compressor or fans may not start
|
Compressor Relay / Driver Fault | View Details |
| F1 |
Display shows F1 and unit may shut down or run erratically
|
General Control Board Fault | View Details |
| F2 |
Display shows F2 and interior light or fan may not operate correctly
|
Fan or Light Output Fault | View Details |
| F3 |
Display shows F3 and temperature readings are obviously incorrect
|
Temperature Calibration / Sensor Range Fault | View Details |
| H1 |
Display shows H1 and interior temperature is very warm
|
High Temperature Alarm Condition | View Details |
| L1 |
Display shows L1 and interior temperature is very cold, bottles may be frosting
|
Low Temperature Alarm Condition | View Details |
| LC |
Display shows LC and controls are locked, buttons do not respond
|
Control Lock (Child Lock) Active | View Details |
| – |
Buttons on the control panel do not respond or respond intermittently
|
Keypad / Touch Control Failure | View Details |
| – |
Cabinet or door exterior feels hot to the touch
|
High Cabinet Surface Temperature | View Details |
| – |
Chemical or plastic smell from new or recently installed wine cooler
|
New Appliance Odor / Off‑gassing | View Details |
| – |
Clicking sound from compressor area, compressor tries to start then stops repeatedly
|
Compressor Hard Start / Short Cycling | View Details |
| – |
Compressor and fans run continuously, unit rarely cycles off
|
Continuous Run / Overcooling Attempt | View Details |
| – |
Condensation or moisture forming on the inside of the glass door
|
Door Condensation / High Humidity | View Details |
| – |
Condensation or water droplets forming on interior walls and shelves
|
Interior Condensation | View Details |
| – |
Display is blank or very dim, but unit still cools
|
Display / User Interface Failure | View Details |
| – |
Door does not close properly or pops open, temperature fluctuates
|
Door Alignment / Gasket Failure | View Details |
| – |
Excessive frost or ice buildup on interior back wall or evaporator cover
|
Frost Buildup / Defrost System Failure | View Details |
| – |
Interior light does not turn on when door is opened
|
Interior Light Failure | View Details |
| – |
Interior light stays on even when the door is closed, cabinet may get warm
|
Light Stuck On / Door Switch Fault | View Details |
| – |
Loud humming, buzzing, or rattling noise during operation
|
Excessive Noise / Vibration | View Details |
| – |
Lower zone cools but upper zone is warm (dual‑zone model)
|
Upper Zone Cooling Failure (Dual‑Zone) | View Details |
| – |
Strong musty or moldy odor inside the wine cooler
|
Odor / Biological Growth | View Details |
| – |
Temperature fluctuates widely, wines too warm at times and too cold at others
|
Temperature Instability | View Details |
| – |
Unit cycles on and off very frequently, short run times
|
Short Cycling | View Details |
| – |
Unit does not power on at all, no lights or display
|
No Power / Dead Unit | View Details |
| – |
Unit trips the household circuit breaker or GFCI outlet
|
Electrical Short / Ground Fault | View Details |
| – |
Upper zone cools but lower zone is warm (dual‑zone model)
|
Single Zone Cooling Failure (Dual‑Zone) | View Details |
| – |
Water pooling at the bottom of the cabinet or leaking onto the floor
|
Drainage / Condensate Leak | View Details |
| – |
Wine cooler not cooling at all, interior at room temperature, display may still light
|
No Cooling / Compressor Not Running | View Details |
| – |
Wine cooler runs but does not get cold enough, temperature stays above setpoint
|
Insufficient Cooling / Warm Cabinet | View Details |
No matching codes found
Advertisements