Gorenje Loss of Zone Separation

Dual-zone wine cooler shows correct temperatures but both zones feel the same and do not maintain separate conditions.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty or stuck inter-zone damper, Inter-zone fan running continuously, Damaged insulation between zones, Control logic error on PCB

How to Fix / Troubleshooting

Safety: Unplug the appliance before removing internal panels.

  • Inspect partition: Remove the central partition cover and check for a mechanical damper or flap that may be stuck open.
  • Test damper operation: Manually move the damper to ensure it is not jammed. Replace the damper assembly if broken.
  • Check inter-zone fan: Ensure the fan only runs when required. If it runs constantly regardless of settings, suspect a PCB fault.
  • PCB reset/replacement: Try a power reset. If the issue persists and hardware is intact, the control PCB may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Inter-Zone Damper Assembly
Check Price on Amazon