F2
Gorenje
Lower Zone Temperature Sensor Fault
Lower zone of a dual-zone Gorenje wine cooler shows F2 and does not reach set temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed lower zone NTC sensor, Loose or broken sensor wiring, Connector corrosion at PCB, Faulty lower zone sensor input on PCB
How to Fix / Troubleshooting
Safety: Disconnect power before working inside the cabinet.
- Locate lower zone sensor: Remove lower shelves and the rear or side interior panel to access the sensor.
- Inspect wiring: Look for damage from bottles, shelves, or condensation. Reseat the connector.
- Test sensor: Measure resistance and compare to expected NTC values. Replace if open, shorted, or clearly incorrect.
- Reassemble and test: Fit a new Gorenje-compatible sensor if needed, reassemble, and confirm that F2 disappears and the lower zone cools properly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Lower Zone NTC Temperature Sensor
Check Price on Amazon