Lo
Gorenje
Low Temperature Alarm / Overcooling Fault
Display shows Lo or a low temperature warning; interior may be colder than set point and bottles may frost.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on main PCB keeping compressor on, Faulty temperature sensor reading too warm, Control calibration error, Incorrect setpoint or demo mode disabled incorrectly
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
- Verify setpoint: Confirm that the temperature is not set too low for the wine type. Adjust to recommended values (typically 5–18°C depending on zone).
- Power reset: Unplug for 10 minutes, then reconnect to clear any temporary control glitches.
- Check sensor accuracy: Place an accurate thermometer inside and compare to the displayed temperature. If the display is significantly higher than actual, the sensor may be faulty (see E1/E2/E3 procedures).
- Inspect PCB relay: If the compressor runs almost constantly and the cabinet is too cold, the compressor relay on the PCB may be stuck closed. Replace the main control PCB if this is confirmed.