Gorenje
Evaporator Fan Not Running
Interior fan does not run; cold spots and warm spots develop inside the cabinet.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator fan motor, Ice blocking fan, Loose wiring to fan, Faulty fan control on PCB
How to Fix / Troubleshooting
Safety: Unplug the wine cooler before accessing the fan.
- Access and inspect fan: Remove the rear interior panel to expose the fan. Check for ice or debris blocking the blades.
- Defrost if needed: Fully defrost the unit if ice is present.
- Test fan motor: Spin by hand and check for smooth movement. Replace the motor if seized or noisy.
- Check wiring and voltage: Verify connections and, with caution, measure voltage when the fan should run. Replace the fan or PCB as indicated by tests.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Fan Motor
Check Price on Amazon