Gorenje Evaporator Fan Not Running

Interior fan does not run; cold spots and warm spots develop inside the cabinet.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan motor, Ice blocking fan, Loose wiring to fan, Faulty fan control on PCB

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before accessing the fan.

  • Access and inspect fan: Remove the rear interior panel to expose the fan. Check for ice or debris blocking the blades.
  • Defrost if needed: Fully defrost the unit if ice is present.
  • Test fan motor: Spin by hand and check for smooth movement. Replace the motor if seized or noisy.
  • Check wiring and voltage: Verify connections and, with caution, measure voltage when the fan should run. Replace the fan or PCB as indicated by tests.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon