E11
Hotpoint Interior Light Circuit Fault

E11 displayed, interior light may flicker or stay on, door alarm may sound incorrectly

Advertisements

Possible Causes

Shorted LED light module, Damaged light wiring harness, Failed light driver on main PCB, Incorrect door switch signal

How to Fix / Troubleshooting

Safety: Unplug the appliance before working on the light assembly.

  • Check light behavior: Note if the light is stuck on, off, or flickering when the door is opened and closed.
  • Inspect LED module: Remove the light cover inside the cabinet. Look for burn marks or discoloration on the LED board.
  • Test door switch: Ensure the door switch operates correctly, as a stuck switch can confuse the light circuit.
  • Disconnect light module: Temporarily unplug the LED module from its connector. Restore power briefly to see if E11 clears (then unplug again). If the error disappears, the light module is likely faulty.
  • Replace LED light module: Install a Hotpoint-compatible LED assembly. Do not substitute with non-rated parts, as heat and voltage must match.
  • If E11 remains with light disconnected: The light driver on the main control board may be damaged and the board may need replacement by a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.