E16
Hotpoint
Compressor Relay / Output Fault
E16 displayed, compressor and fan may not start, unit appears powered but does not cool
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor relay on main PCB, Burnt relay contacts from high current, Broken output trace on PCB, Loose compressor output connector
How to Fix / Troubleshooting
Safety: Unplug the wine cooler. High voltage is present on the control board.
- Confirm compressor is functional: If previously tested or replaced, assume compressor is good and focus on control output.
- Inspect main board: Look for a relay labeled for the compressor. Check for burn marks or cracked solder joints around it.
- Reseat output connectors: Ensure the harness from the board to the compressor start device is firmly connected.
- Check for loose solder: For advanced DIYers, inspect the underside of the PCB for cracked solder joints at the relay pins and reflow if skilled and safe to do so.
- Replace main control board: If the relay is visibly damaged or E16 persists, install a new Hotpoint control board.
- Do not bypass safety circuits: Never hard-wire the compressor to run continuously; this is unsafe and can cause fire or compressor damage.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.