dE
Kalamera
Door Switch or Door Sensor Error
Display shows dE and the door alarm sounds even when the door appears closed.
Advertisements
Possible Causes
Misaligned door magnet or reed switch, Failed door switch, Broken door switch wiring, Loose connector at control board
How to Fix / Troubleshooting
Safety: Unplug the unit before working around the door frame or control wiring.
Steps:
- 1. Check door closure: Ensure the door is fully closing and that shelves or bottles are not preventing a tight seal. Inspect the gasket for deformation.
- 2. Locate door sensor: On many Kalamera models, a magnetic reed switch is mounted in the cabinet frame, and a magnet is embedded in the door. Others use a mechanical plunger switch.
- 3. Test the switch: If accessible, remove the inner trim to expose the switch. With the unit unplugged, disconnect the switch and test continuity with a multimeter while opening and closing the door (or moving a magnet near the reed switch). The reading should change between open and closed.
- 4. Adjust alignment: If using a magnetic sensor, ensure the door magnet lines up directly with the switch when closed. Adjust the door hinges or magnet position if necessary.
- 5. Replace faulty switch: If the switch does not change state, replace it with a compatible Kalamera door switch or reed sensor. Reconnect wiring securely.
- 6. Test alarm: Restore power and verify that the dE code and alarm clear when the door is closed and reappear when opened.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Magnetic Reed Sensor
Check Price on Amazon
We may earn a commission from links on this page.