Kalamera Defrost System Inefficiency or Air Leak

Frost or ice buildup on the back wall or around the evaporator.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Door gasket leak allowing moist air in, Defrost sensor out of position, Partial defrost heater failure, Blocked air circulation around evaporator

How to Fix / Troubleshooting

Safety: Unplug the cooler before defrosting or accessing the evaporator area.

Steps:

  • 1. Manual defrost: Remove all bottles, unplug the unit, and leave the door open to allow ice to melt. Place towels to catch water. Do not use sharp tools to chip ice.
  • 2. Check door seal: Inspect and replace the door gasket if it is not sealing properly, as this is a common cause of excess frost.
  • 3. Inspect evaporator area: After defrosting, remove the rear interior panel and check that the evaporator fan and defrost sensor are correctly positioned and not covered in ice.
  • 4. Test defrost sensor and heater: Use a multimeter to check the defrost thermistor and heater for continuity. Replace any components that test open or out of range.
  • 5. Restore and monitor: Reassemble, plug in, and monitor for several days. If heavy frost returns quickly, further diagnosis of the defrost system or control board may be needed.
Advertisements

Repair Difficulty

Medium 3/5