Kalamera Overcooling / Thermostat or Sensor Out of Calibration

Wine cooler is too cold; bottles or beverages are freezing even at moderate setpoints.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty cabinet thermistor reading too warm, Stuck compressor relay on control board, Incorrect sensor placement, Control board calibration error

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

Steps:

  • 1. Verify with a thermometer: Place an accurate thermometer inside the cabinet and compare to the display. If the actual temperature is much lower, the sensor or control is misreading.
  • 2. Inspect cabinet thermistor: Locate the interior temperature sensor on the rear wall. Ensure it is not touching the evaporator directly or positioned in a cold air stream that could skew readings.
  • 3. Test thermistor: Disconnect and measure resistance with a multimeter. Compare to expected NTC values at the measured temperature. Replace if out of range.
  • 4. Check control board relay: If the compressor runs almost constantly even when the setpoint is reached, the compressor relay on the main board may be stuck closed. Replace the main control board if confirmed.
  • 5. Adjust setpoint and monitor: Temporarily raise the set temperature and observe whether the compressor cycles off. If not, control board replacement is likely required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet Temperature Sensor (NTC Thermistor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements