E4
Liebherr Defrost Sensor / Evaporator Sensor Error (Alternate Code)

E4 displayed; defrost issues or irregular compressor cycling may be observed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misreading evaporator NTC sensor, Sensor not properly attached to evaporator, Wiring harness partially broken causing intermittent readings

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the evaporator area.

Steps:

  • 1. Access evaporator: Remove interior rear panel to expose the evaporator and attached sensor.
  • 2. Check sensor mounting: Ensure the sensor is firmly clipped to the evaporator tube and has good thermal contact.
  • 3. Inspect wiring: Flex the harness gently while checking for visible cracks or kinks that could cause intermittent contact.
  • 4. Test sensor: Measure resistance and compare with cabinet sensor or manufacturer data.
  • 5. Replace sensor: If readings are unstable or out of range, install a new Liebherr evaporator NTC sensor.

Note: If E4 persists with a known-good sensor, the control board's sensor input may be defective.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements