AL
Display shows AL or flashes temperature with an alarm symbol; interior is too warm.
High Temperature Alarm
d1
Display shows d1 or door symbol; audible alarm sounds; unit may stop cooling after prolonged door open.
Door Open Alarm / Door Switch Fault
E1
E1 displayed on dual-zone Liebherr wine cooler; one zone not controlling temperature correctly.
Upper Zone Temperature Sensor Fault
E2
E2 displayed on dual-zone Liebherr wine cooler; lower zone temperature unstable or not cooling.
Lower Zone Temperature Sensor Fault
E3
E3 displayed; fan symbol may flash; poor air circulation between zones.
Circulation Fan / Cross-Flow Fan Fault
E4
E4 displayed; defrost issues or irregular compressor cycling may be observed.
Defrost Sensor / Evaporator Sensor Error (Alternate Code)
E5
E5 displayed; compressor may not start; unit remains warm.
Compressor Control / Inverter Fault (on inverter models)
E6
E6 displayed; interior lighting may fail or flicker; cooler otherwise operates.
LED Lighting Circuit Fault
E7
E7 displayed; humidity control not functioning correctly on models with active humidification.
Humidity Sensor / Humidification System Fault
F0
Wine cooler runs but cannot reach set temperature; display may show F0 and interior feels too warm.
Cabinet Temperature Sensor Failure
F1
Wine cooler shows F1 and may overcool or not cool correctly; temperature display may be inaccurate.
Evaporator Temperature Sensor Failure
F2
Display shows F2 and the wine cooler may not regulate temperature correctly; compressor may run continuously or not at all.
Ambient Temperature Sensor Failure
F3
F3 displayed; interior light and fan may behave erratically; temperature control may be unstable.
Control Panel / Keypad Temperature Sensor or Interface Fault
F4
F4 error displayed; compressor may not start or may shut down quickly; unit not cooling.
Compressor Start / Relay Circuit Fault
F5
F5 displayed; interior fan may not run; temperature stratification (warm at top, cold at bottom).
Evaporator Fan Motor Fault
F6
F6 error; unit may not defrost properly, leading to ice buildup on the back wall and poor cooling.
Defrost Heater or Defrost Circuit Fault
F7
F7 displayed; compressor may not run; unit remains warm despite power being on.
Compressor Overload or High-Temperature Protection Fault
F8
F8 error; interior light and display may flicker; unit may randomly restart or shut down.
Power Supply / Low Voltage Fault
F9
F9 displayed; audible alarm may sound; temperature may drift and not match setpoint.
Communication Fault Between User Interface and Main Control Board
Lo
Display shows Lo or very low temperature; bottles may be over-chilled or partially frozen.
Overcooling / Thermostat Control Fault
Symptom
Buttons on the control panel do not respond or respond intermittently.
Keypad / Touch Control Failure
Symptom
Cabinet exterior sides feel very hot to the touch during operation.
Condenser Heat Transfer / Ventilation Issue
Symptom
Clicking sound every few minutes; compressor attempts to start but stops quickly; little or no cooling.
Compressor Start Failure
Symptom
Condensation forming on the outside of the door or around the frame.
Excess External Condensation
Symptom
Display is blank or unreadable, but interior light and cooling still work.
Display / User Interface Failure
Symptom
Door does not close properly or pops open slightly after being shut.
Door Alignment / Hinge or Gasket Issue
Symptom
Excessive frost or ice buildup on the back wall or around the evaporator; fan noise may increase.
Defrost System Failure or Door Seal Leak
Symptom
High-pitched squealing or grinding noise from inside the cabinet when cooling.
Evaporator Fan Bearing Wear
Symptom
Interior humidity too high; condensation on bottles and shelves.
Excess Humidity in Cabinet
Symptom
Interior humidity too low; corks appear dry on models with humidity control.
Insufficient Humidification
Symptom
Interior light not working but cooler otherwise operates normally.
Lighting Circuit Failure
Symptom
Loud humming, rattling, or vibrating noise during operation; noise may change when door is opened.
Mechanical Vibration or Fan/Compressor Mounting Issue
Symptom
Strong musty or moldy odor inside the wine cooler.
Microbial Growth Due to High Humidity or Spills
Symptom
Temperature difference between top and bottom shelves is larger than expected; stratification of temperature.
Poor Air Circulation
Symptom
Vibration transmitted to cabinetry or floor, causing rattling noises in surrounding furniture.
Installation / Isolation Issue
Symptom
Water pooling at the bottom of the wine cooler or on the floor in front of the unit.
Condensate Drain Blockage or Excess Condensation
Symptom
Wine cooler cycles on and off very frequently (short cycling).
Control or Sensor Instability
Symptom
Wine cooler interior too cold; bottles freezing near back wall despite normal set temperature.
Thermostat / Sensor Calibration Error
Symptom
Wine cooler not cooling at all; interior at room temperature; display and lights work but no cold air.
Compressor or Sealed System Failure
Symptom
Wine cooler not starting at all; display and lights are off; no signs of power.
No Power / Main Supply Fault
Symptom
Wine cooler runs continuously but does not reach set temperature; interior is cool but not cold enough.
Partial Refrigerant Loss or Reduced Cooling Capacity
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| AL |
Display shows AL or flashes temperature with an alarm symbol; interior is too warm.
|
High Temperature Alarm | View Details |
| d1 |
Display shows d1 or door symbol; audible alarm sounds; unit may stop cooling after prolonged door open.
|
Door Open Alarm / Door Switch Fault | View Details |
| E1 |
E1 displayed on dual-zone Liebherr wine cooler; one zone not controlling temperature correctly.
|
Upper Zone Temperature Sensor Fault | View Details |
| E2 |
E2 displayed on dual-zone Liebherr wine cooler; lower zone temperature unstable or not cooling.
|
Lower Zone Temperature Sensor Fault | View Details |
| E3 |
E3 displayed; fan symbol may flash; poor air circulation between zones.
|
Circulation Fan / Cross-Flow Fan Fault | View Details |
| E4 |
E4 displayed; defrost issues or irregular compressor cycling may be observed.
|
Defrost Sensor / Evaporator Sensor Error (Alternate Code) | View Details |
| E5 |
E5 displayed; compressor may not start; unit remains warm.
|
Compressor Control / Inverter Fault (on inverter models) | View Details |
| E6 |
E6 displayed; interior lighting may fail or flicker; cooler otherwise operates.
|
LED Lighting Circuit Fault | View Details |
| E7 |
E7 displayed; humidity control not functioning correctly on models with active humidification.
|
Humidity Sensor / Humidification System Fault | View Details |
| F0 |
Wine cooler runs but cannot reach set temperature; display may show F0 and interior feels too warm.
|
Cabinet Temperature Sensor Failure | View Details |
| F1 |
Wine cooler shows F1 and may overcool or not cool correctly; temperature display may be inaccurate.
|
Evaporator Temperature Sensor Failure | View Details |
| F2 |
Display shows F2 and the wine cooler may not regulate temperature correctly; compressor may run continuously or not at all.
|
Ambient Temperature Sensor Failure | View Details |
| F3 |
F3 displayed; interior light and fan may behave erratically; temperature control may be unstable.
|
Control Panel / Keypad Temperature Sensor or Interface Fault | View Details |
| F4 |
F4 error displayed; compressor may not start or may shut down quickly; unit not cooling.
|
Compressor Start / Relay Circuit Fault | View Details |
| F5 |
F5 displayed; interior fan may not run; temperature stratification (warm at top, cold at bottom).
|
Evaporator Fan Motor Fault | View Details |
| F6 |
F6 error; unit may not defrost properly, leading to ice buildup on the back wall and poor cooling.
|
Defrost Heater or Defrost Circuit Fault | View Details |
| F7 |
F7 displayed; compressor may not run; unit remains warm despite power being on.
|
Compressor Overload or High-Temperature Protection Fault | View Details |
| F8 |
F8 error; interior light and display may flicker; unit may randomly restart or shut down.
|
Power Supply / Low Voltage Fault | View Details |
| F9 |
F9 displayed; audible alarm may sound; temperature may drift and not match setpoint.
|
Communication Fault Between User Interface and Main Control Board | View Details |
| Lo |
Display shows Lo or very low temperature; bottles may be over-chilled or partially frozen.
|
Overcooling / Thermostat Control Fault | View Details |
| – |
Buttons on the control panel do not respond or respond intermittently.
|
Keypad / Touch Control Failure | View Details |
| – |
Cabinet exterior sides feel very hot to the touch during operation.
|
Condenser Heat Transfer / Ventilation Issue | View Details |
| – |
Clicking sound every few minutes; compressor attempts to start but stops quickly; little or no cooling.
|
Compressor Start Failure | View Details |
| – |
Condensation forming on the outside of the door or around the frame.
|
Excess External Condensation | View Details |
| – |
Display is blank or unreadable, but interior light and cooling still work.
|
Display / User Interface Failure | View Details |
| – |
Door does not close properly or pops open slightly after being shut.
|
Door Alignment / Hinge or Gasket Issue | View Details |
| – |
Excessive frost or ice buildup on the back wall or around the evaporator; fan noise may increase.
|
Defrost System Failure or Door Seal Leak | View Details |
| – |
High-pitched squealing or grinding noise from inside the cabinet when cooling.
|
Evaporator Fan Bearing Wear | View Details |
| – |
Interior humidity too high; condensation on bottles and shelves.
|
Excess Humidity in Cabinet | View Details |
| – |
Interior humidity too low; corks appear dry on models with humidity control.
|
Insufficient Humidification | View Details |
| – |
Interior light not working but cooler otherwise operates normally.
|
Lighting Circuit Failure | View Details |
| – |
Loud humming, rattling, or vibrating noise during operation; noise may change when door is opened.
|
Mechanical Vibration or Fan/Compressor Mounting Issue | View Details |
| – |
Strong musty or moldy odor inside the wine cooler.
|
Microbial Growth Due to High Humidity or Spills | View Details |
| – |
Temperature difference between top and bottom shelves is larger than expected; stratification of temperature.
|
Poor Air Circulation | View Details |
| – |
Vibration transmitted to cabinetry or floor, causing rattling noises in surrounding furniture.
|
Installation / Isolation Issue | View Details |
| – |
Water pooling at the bottom of the wine cooler or on the floor in front of the unit.
|
Condensate Drain Blockage or Excess Condensation | View Details |
| – |
Wine cooler cycles on and off very frequently (short cycling).
|
Control or Sensor Instability | View Details |
| – |
Wine cooler interior too cold; bottles freezing near back wall despite normal set temperature.
|
Thermostat / Sensor Calibration Error | View Details |
| – |
Wine cooler not cooling at all; interior at room temperature; display and lights work but no cold air.
|
Compressor or Sealed System Failure | View Details |
| – |
Wine cooler not starting at all; display and lights are off; no signs of power.
|
No Power / Main Supply Fault | View Details |
| – |
Wine cooler runs continuously but does not reach set temperature; interior is cool but not cold enough.
|
Partial Refrigerant Loss or Reduced Cooling Capacity | View Details |
No matching codes found
Advertisements