Liebherr Control or Sensor Instability

Wine cooler cycles on and off very frequently (short cycling).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Temperature sensor located too close to cold air outlet, Oversensitive control algorithm due to faulty sensor, Ambient temperature fluctuations or drafts around cabinet

How to Fix / Troubleshooting

Safety first: Unplug the unit before moving sensors or accessing the control board.

Steps:

  • 1. Check installation: Ensure the cooler is not installed near heat sources or in direct sunlight, and that room temperature is stable.
  • 2. Inspect sensor placement: Confirm the cabinet sensor is in its original position and not directly in the cold air stream.
  • 3. Reset control: Disconnect power for 5 minutes to reset the control logic.
  • 4. Replace sensor: If short cycling persists, replace the cabinet NTC sensor.
  • 5. Professional diagnosis: If unresolved, the main control board may require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor / Main Control Board