Luma Single-Zone Cooling Failure in Dual-Zone System

Dual-zone Luma wine cooler: upper zone cools but lower zone is warm (or vice versa).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed zone-specific evaporator fan, Blocked air duct between zones, Faulty zone temperature sensor, Zone valve or damper stuck (if equipped)

How to Fix / Troubleshooting

Disconnect power before accessing internal ducts or fans.

  • Compare zones: Note which zone is not cooling. Listen for fan noise in both zones.
  • Inspect fan and ducts: Remove the interior panel for the affected zone and check the Luma zone evaporator fan and air ducts for obstructions or ice.
  • Test sensor: Check the zone’s temperature sensor for secure mounting and proper resistance. Replace if faulty.
  • Damper/valve: On models with a mechanical damper between zones, ensure it moves freely and is not stuck closed.

If one zone’s cooling hardware (fan, sensor) is failed, replacing those components usually restores proper dual-zone operation.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator Fan or Zone Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements