NewAir Auxiliary Output or Light Circuit Fault

Display shows F2; interior light or other auxiliary functions may not operate correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted LED light module, Damaged light wiring harness, Failed light driver circuit on main control board

How to Fix / Troubleshooting

Safety: Unplug the cooler before working on the light or wiring. LED modules operate at low voltage but are powered from mains circuitry.

Steps to address F2:

  • Check light behavior: Note whether the interior light is stuck on, will not turn on, or flickers when F2 appears.
  • Inspect LED module: Remove the light cover inside the cabinet and inspect the LED module for burn marks or discoloration.
  • Check wiring: Follow the light wires to their connector. Look for pinched or cut wires, especially where they pass through the liner.
  • Disconnect light module: With power unplugged, disconnect the LED module from the harness. Restore power briefly to see if F2 clears without the light connected (do this only if you are comfortable; otherwise, skip and call a technician).
  • Replace faulty LED module: If F2 clears when the light is disconnected, replace the NewAir LED light module and reconnect.
  • Evaluate control board: If F2 persists even with the light disconnected and wiring intact, the light driver on the main control board may be defective. Replace the NewAir main control board (PCB) as needed.

Note: Do not bypass or jumper light circuits; this can damage the control board and create a fire hazard.