Interior fan runs but compressor does not start; cabinet slowly warms up.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the cooler before accessing the compressor and control board. Only work with live voltage if you are trained and equipped.
Steps to diagnose no compressor operation:
- Listen for compressor: Confirm that only the fan is running and the compressor is silent.
- Check control settings: Ensure the unit is not in standby mode and that the set temperature is below room temperature.
- Inspect start relay and overload: Remove the compressor terminal cover and examine the relay/overload assembly for damage.
- Test relay and overload: With a multimeter, check continuity of the overload and resistance of the relay. Replace with a NewAir compressor start relay and overload protector if faulty.
- Check control board output: A technician can verify whether the main board is sending power to the compressor when cooling is demanded. If not, replace the NewAir main control board (PCB).
Warning: If the compressor windings are open or shorted, the compressor must be replaced by a licensed refrigeration technician.