E14
Pevino
Refrigeration System Efficiency Fault
Display shows E14 and the unit may not reach set temperature even though fans and compressor run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partial refrigerant leak in sealed system, Blocked capillary tube or filter drier, Weak compressor, Severely frosted evaporator reducing heat transfer
How to Fix / Troubleshooting
Safety: Unplug the cooler before any inspection. Sealed system work involves high pressure and refrigerant and must be done by certified technicians.
- Check for frost pattern: Remove the interior back panel and observe the evaporator after 10–15 minutes of operation. A normal pattern is even frost across most of the coil. Frost only at the inlet or no frost suggests a sealed system problem.
- Inspect for oil stains: Look around tubing joints and the compressor area for oily residue, which can indicate a refrigerant leak.
- Verify door sealing: Ensure the door gasket seals fully and the door is not being left open, which can mimic poor cooling.
- Call a professional: If a sealed system fault is suspected, contact a licensed refrigeration technician to check pressures, locate leaks, and recharge or replace components as needed.