Pevino Overcooling / Thermostat Control Failure

Wine cooler is too cold; bottles may be near freezing even at higher setpoints.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compartment NTC sensor, Stuck relay on main control board, Incorrect sensor placement touching evaporator, Firmware/control calibration error

How to Fix / Troubleshooting

Safety: Unplug the cooler before accessing sensors or the control board.

  • Verify set temperature: Confirm the displayed setpoint is correct and that no special modes (e.g., fast chill) are active.
  • Check sensor placement: Remove interior panels and ensure the compartment NTC sensors are not taped directly to the evaporator coil, which can cause false low readings.
  • Inspect wiring: Look for damaged or shorted sensor wires that could cause incorrect readings.
  • Replace suspect sensor: If overcooling is confined to one zone, replace that zone's NTC sensor.
  • Control board: If sensors are good and correctly placed, the main control board may have a stuck relay or calibration fault and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Upper Compartment NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.