Noritz
Noritz Water Heaters Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
10
Water heater shuts down and displays error code 10; unit may run briefly then stop, often during high-demand usage.
Exhaust / Air Supply Blockage
11
Water heater will not ignite; display shows error code 11; no hot water at any fixture.
Ignition Failure
12
Burner lights briefly then goes out; display shows error code 12; intermittent hot water that quickly turns cold.
Flame Loss / Flame Rod Detection Failure
14
Unit shuts down with error code 14; may occur after extended operation or at high temperature setpoints.
Thermal Fuse / Overheat Cutoff Activation
16
Water temperature overshoots setpoint; unit shuts down with error code 16, often during low-flow usage such as handwashing.
Outlet Water Overheat
20
Unit displays error code 20 and will not operate; may occur after power issues or internal fault.
Internal Safety Control / High Temperature Limit Fault
29
Error code 29 appears; unit may shut down during operation, especially on condensing Noritz models with condensate drain.
Condensate Drain Blockage / Neutralizer Fault
31
Error code 31 displayed; unit may not start or may shut down shortly after startup.
Inlet Thermistor Fault
32
Error code 32 displayed; unit may operate erratically or shut down.
Outlet Thermistor Fault
33
Error code 33 appears; unit may not modulate correctly or may shut down.
Heat Exchanger Thermistor Fault
34
Error code 34 displayed; unit may shut down or fail to start.
Combustion Air Temperature Sensor Fault
38
Error code 38 appears; unit may not fire or may shut down shortly after ignition.
CO2 / Combustion Feedback Abnormality
41
Error code 41 displayed; unit may not start or may shut down unexpectedly.
Freeze Protection Sensor Fault
42
Error code 42 appears; unit may not fire or may shut down intermittently.
Fan Motor / Combustion Fan Abnormality
43
Error code 43 displayed; unit may not operate.
Internal Circulation Pump / Flow Control Fault (models equipped with pump)
45
Error code 45 appears; unit may not operate in recirculation mode.
External Recirculation Pump / Control Fault
51
Error code 51 displayed; unit may not respond correctly to remote controller commands.
Remote Controller Communication Fault
52
Error code 52 appears; unit may not fire or may shut down.
Modulating Gas Valve Signal Fault
57
Error code 57 displayed; unit may shut down during operation.
Burner Overheat / Abnormal Combustion
61
Error code 61 appears; unit may not start or may shut down.
Combustion Fan Motor Lock / Speed Fault
65
Error code 65 displayed; unit may not operate correctly in recirculation or may shut down.
Flow Control Valve / Bypass Valve Fault
66
Error code 66 appears; unit may not modulate water flow correctly.
Bypass Flow Control Valve Fault
67
Error code 67 displayed; unit may not start.
PCB / Control Board Fault
70
Error code 70 appears; unit may not operate or may behave erratically.
Internal PCB Configuration / Parameter Fault
71
Error code 71 displayed; unit may not operate.
Gas Valve Drive Circuit Fault
72
Error code 72 appears; unit may not detect flame correctly.
Flame Sensing Circuit Abnormality
73
Error code 73 displayed; unit may not operate after service or configuration changes.
Parameter Setting / Dip Switch Conflict
90
Error code 90 appears; unit may shut down during operation.
Abnormal Combustion / Gas Combustion Fault
92
Error code 92 displayed; unit may not operate.
Fan Speed / Combustion Feedback Fault
93
Error code 93 appears; unit may shut down or fail to start.
Combustion Control / Feedback Fault
94
Error code 94 displayed; unit may shut down during operation.
Flame Loss During Operation / Combustion Abnormality
95
Error code 95 appears; unit may not operate.
Abnormal Internal Temperature / Overheat Protection
99
Error code 99 displayed; unit shuts down and will not operate.
Flame Detection Failure / Safety Lockout
Symptom
Hot water temperature fluctuates between hot and cold during a shower; no error code displayed.
Temperature Fluctuation / Short Cycling
Symptom
No hot water anywhere in the home; Noritz water heater display is blank (no power).
No Power to Water Heater
Symptom
No hot water; Noritz unit has power but does not start when hot water taps are opened (no error code displayed).
Flow Sensor Not Detecting Demand
Symptom
Noritz water heater cycles on and off rapidly when a small hot water demand is present (e.g., handwashing).
Short Cycling at Low Flow
Symptom
Noritz water heater exhaust smells strongly of gas or combustion fumes; occupants may notice headaches or irritation.
Combustion / Venting Safety Issue
Symptom
Noritz water heater fan runs but burner does not ignite; no error code displayed, intermittent issue.
Intermittent Ignition / Weak Spark
Symptom
Noritz water heater frequently shuts off when multiple fixtures are used simultaneously; water goes cold until some fixtures are closed.
Capacity Overload / Flow Exceeds Heater Rating
Symptom
Noritz water heater installed outdoors will not operate in cold weather; visible ice or frost on piping or unit.
Freeze Protection Failure / Frozen Piping
Symptom
Noritz water heater is leaking water from the bottom of the unit or from internal components.
Internal Water Leak
Symptom
Noritz water heater makes loud banging or popping noises during operation.
Scale Buildup / Kettling in Heat Exchanger
Symptom
Remote controller for Noritz water heater is unresponsive or displays no information, while the heater itself appears to operate.
Remote Controller Power / Communication Issue
Symptom
Water is warm but not reaching the set temperature; Noritz unit runs continuously without error codes.
Insufficient Heating / Under-Firing
Symptom
Water leaking from the pressure relief valve discharge pipe near the Noritz water heater.
Relief Valve Discharge / Overpressure or Overtemperature
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| 10 |
Water heater shuts down and displays error code 10; unit may run briefly then stop, often during high-demand usage.
|
Exhaust / Air Supply Blockage | View Details |
| 11 |
Water heater will not ignite; display shows error code 11; no hot water at any fixture.
|
Ignition Failure | View Details |
| 12 |
Burner lights briefly then goes out; display shows error code 12; intermittent hot water that quickly turns cold.
|
Flame Loss / Flame Rod Detection Failure | View Details |
| 14 |
Unit shuts down with error code 14; may occur after extended operation or at high temperature setpoints.
|
Thermal Fuse / Overheat Cutoff Activation | View Details |
| 16 |
Water temperature overshoots setpoint; unit shuts down with error code 16, often during low-flow usage such as handwashing.
|
Outlet Water Overheat | View Details |
| 20 |
Unit displays error code 20 and will not operate; may occur after power issues or internal fault.
|
Internal Safety Control / High Temperature Limit Fault | View Details |
| 29 |
Error code 29 appears; unit may shut down during operation, especially on condensing Noritz models with condensate drain.
|
Condensate Drain Blockage / Neutralizer Fault | View Details |
| 31 |
Error code 31 displayed; unit may not start or may shut down shortly after startup.
|
Inlet Thermistor Fault | View Details |
| 32 |
Error code 32 displayed; unit may operate erratically or shut down.
|
Outlet Thermistor Fault | View Details |
| 33 |
Error code 33 appears; unit may not modulate correctly or may shut down.
|
Heat Exchanger Thermistor Fault | View Details |
| 34 |
Error code 34 displayed; unit may shut down or fail to start.
|
Combustion Air Temperature Sensor Fault | View Details |
| 38 |
Error code 38 appears; unit may not fire or may shut down shortly after ignition.
|
CO2 / Combustion Feedback Abnormality | View Details |
| 41 |
Error code 41 displayed; unit may not start or may shut down unexpectedly.
|
Freeze Protection Sensor Fault | View Details |
| 42 |
Error code 42 appears; unit may not fire or may shut down intermittently.
|
Fan Motor / Combustion Fan Abnormality | View Details |
| 43 |
Error code 43 displayed; unit may not operate.
|
Internal Circulation Pump / Flow Control Fault (models equipped with pump) | View Details |
| 45 |
Error code 45 appears; unit may not operate in recirculation mode.
|
External Recirculation Pump / Control Fault | View Details |
| 51 |
Error code 51 displayed; unit may not respond correctly to remote controller commands.
|
Remote Controller Communication Fault | View Details |
| 52 |
Error code 52 appears; unit may not fire or may shut down.
|
Modulating Gas Valve Signal Fault | View Details |
| 57 |
Error code 57 displayed; unit may shut down during operation.
|
Burner Overheat / Abnormal Combustion | View Details |
| 61 |
Error code 61 appears; unit may not start or may shut down.
|
Combustion Fan Motor Lock / Speed Fault | View Details |
| 65 |
Error code 65 displayed; unit may not operate correctly in recirculation or may shut down.
|
Flow Control Valve / Bypass Valve Fault | View Details |
| 66 |
Error code 66 appears; unit may not modulate water flow correctly.
|
Bypass Flow Control Valve Fault | View Details |
| 67 |
Error code 67 displayed; unit may not start.
|
PCB / Control Board Fault | View Details |
| 70 |
Error code 70 appears; unit may not operate or may behave erratically.
|
Internal PCB Configuration / Parameter Fault | View Details |
| 71 |
Error code 71 displayed; unit may not operate.
|
Gas Valve Drive Circuit Fault | View Details |
| 72 |
Error code 72 appears; unit may not detect flame correctly.
|
Flame Sensing Circuit Abnormality | View Details |
| 73 |
Error code 73 displayed; unit may not operate after service or configuration changes.
|
Parameter Setting / Dip Switch Conflict | View Details |
| 90 |
Error code 90 appears; unit may shut down during operation.
|
Abnormal Combustion / Gas Combustion Fault | View Details |
| 92 |
Error code 92 displayed; unit may not operate.
|
Fan Speed / Combustion Feedback Fault | View Details |
| 93 |
Error code 93 appears; unit may shut down or fail to start.
|
Combustion Control / Feedback Fault | View Details |
| 94 |
Error code 94 displayed; unit may shut down during operation.
|
Flame Loss During Operation / Combustion Abnormality | View Details |
| 95 |
Error code 95 appears; unit may not operate.
|
Abnormal Internal Temperature / Overheat Protection | View Details |
| 99 |
Error code 99 displayed; unit shuts down and will not operate.
|
Flame Detection Failure / Safety Lockout | View Details |
| – |
Hot water temperature fluctuates between hot and cold during a shower; no error code displayed.
|
Temperature Fluctuation / Short Cycling | View Details |
| – |
No hot water anywhere in the home; Noritz water heater display is blank (no power).
|
No Power to Water Heater | View Details |
| – |
No hot water; Noritz unit has power but does not start when hot water taps are opened (no error code displayed).
|
Flow Sensor Not Detecting Demand | View Details |
| – |
Noritz water heater cycles on and off rapidly when a small hot water demand is present (e.g., handwashing).
|
Short Cycling at Low Flow | View Details |
| – |
Noritz water heater exhaust smells strongly of gas or combustion fumes; occupants may notice headaches or irritation.
|
Combustion / Venting Safety Issue | View Details |
| – |
Noritz water heater fan runs but burner does not ignite; no error code displayed, intermittent issue.
|
Intermittent Ignition / Weak Spark | View Details |
| – |
Noritz water heater frequently shuts off when multiple fixtures are used simultaneously; water goes cold until some fixtures are closed.
|
Capacity Overload / Flow Exceeds Heater Rating | View Details |
| – |
Noritz water heater installed outdoors will not operate in cold weather; visible ice or frost on piping or unit.
|
Freeze Protection Failure / Frozen Piping | View Details |
| – |
Noritz water heater is leaking water from the bottom of the unit or from internal components.
|
Internal Water Leak | View Details |
| – |
Noritz water heater makes loud banging or popping noises during operation.
|
Scale Buildup / Kettling in Heat Exchanger | View Details |
| – |
Remote controller for Noritz water heater is unresponsive or displays no information, while the heater itself appears to operate.
|
Remote Controller Power / Communication Issue | View Details |
| – |
Water is warm but not reaching the set temperature; Noritz unit runs continuously without error codes.
|
Insufficient Heating / Under-Firing | View Details |
| – |
Water leaking from the pressure relief valve discharge pipe near the Noritz water heater.
|
Relief Valve Discharge / Overpressure or Overtemperature | View Details |
No matching codes found
Advertisements