Ariston

Ariston Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
101
Furnace will not start, display shows error 101, no ignition attempt heard.
No Flame Detected on Start-Up
102
Furnace attempts to ignite but shuts down after a few seconds, error 102 displayed.
Flame Loss During Operation
103
Furnace locks out with error 103, fan runs but no ignition sequence starts.
Ignition Failure / Ignition Lockout
104
Furnace shows error 104 and shuts down shortly after starting, sometimes with rumbling noise.
Flame Detection Error / False Flame Signal
201
Furnace displays error 201, combustion fan does not start, no ignition attempt.
Combustion Fan (Flue Fan) Failure
202
Error 202 appears, furnace starts fan but then shuts down before ignition.
Air Pressure Switch / Fan Proving Failure
203
Furnace intermittently shows error 203, especially in windy conditions.
Flue Draft / Airflow Instability
301
Error 301 displayed, furnace overheats and shuts down, casing feels very warm.
Primary Heat Exchanger Overheat
302
Furnace shows error 302, frequent short cycling, water temperature rises too quickly.
Flow Sensor / Temperature Sensor Fault
303
Error 303, furnace indicates low water flow or no circulation.
Low Water Flow / Flow Switch Fault
304
Furnace displays error 304, high limit trips frequently during operation.
High Limit Thermostat Trip
401
Error 401, furnace will not start, display indicates low system pressure.
Low Water Pressure Lockout
402
Furnace shows error 402, pressure rises rapidly during heating and may vent water from safety valve.
High System Pressure / Expansion Fault
403
Error 403, pressure sensor reading inconsistent or out of range.
Pressure Sensor Electrical Fault
501
Error 501, no flame detected after ignition attempts, repeated lockouts.
Ignition Lockout (General)
502
Error 502, flame detected when there should be none (before ignition or after shutdown).
False Flame Detection
601
Error 601, condensate pump or drain fault, furnace shuts down during operation.
Condensate Drain Blockage
701
Error 701, communication error between user interface and main control board.
Control Board Communication Fault
702
Error 702, EEPROM or configuration error on control board.
Configuration / Memory Fault
801
Error 801, outdoor temperature sensor fault (for weather-compensated systems).
Outdoor Sensor Open/Short
802
Error 802, room thermostat or bus communication fault.
Room Thermostat / Bus Communication Error
Symptom
Furnace causes frequent breaker trips or blows fuses.
Electrical Short or Overload
Symptom
Furnace emits a high-pitched whine or humming noise during operation.
Fan or Pump Noise / Resonance
Symptom
Furnace fan runs continuously even when there is no call for heat.
Fan Stuck On
Symptom
Furnace frequently locks out and requires manual reset, with no consistent error code.
Intermittent Lockout / Unstable Operation
Symptom
Furnace frequently loses pressure over days or weeks without visible leaks.
Hidden System Leak / Expansion Vessel Issue
Symptom
Furnace ignites with a small explosion or loud 'whoomph' sound.
Delayed Ignition
Symptom
Furnace makes loud banging or knocking noises when starting or stopping.
Water Hammer / Expansion Noise
Symptom
Furnace produces a burning smell or hot metal odor when running.
Overheating Components / Dust Burn-Off
Symptom
Furnace runs but produces insufficient heat; home never reaches set temperature.
Underfiring / Low Heat Output
Symptom
Furnace runs but room temperature overshoots the setpoint significantly.
Overheating / Poor Temperature Control
Symptom
Furnace short cycles: starts and stops frequently, with only brief heating periods.
Short Cycling
Symptom
Furnace starts but shuts down after a few minutes, with noticeable overheating of the casing.
Overheating Due to Poor Circulation
Symptom
Furnace will not start at all; no lights on display, no fan, completely dead.
No Power / Dead Furnace
Symptom
Radiators or heating zones are partially warm; some remain cold even when furnace is running.
Imbalanced or Air-Locked Heating System
Symptom
Soot deposits around the flue terminal or on nearby walls.
Sooting / Incomplete Combustion
Symptom
Thermostat calls for heat but furnace does not respond; display shows standby.
No Heat Demand Recognized
Symptom
Visible yellow or unstable flames observed through the inspection window.
Poor Combustion / Incomplete Burning
Symptom
Water leaking from the bottom of the furnace or nearby pipework.
System or Condensate Leak