Triangle Tube

Triangle Tube Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Boiler will not fire, display shows E01 lockout
Ignition Failure Lockout
E02
Boiler shuts down with E02, no flame proven after ignition attempt
Flame Detection Failure
E03
Boiler locks out with E03, no ignition spark observed
Ignition Spark Circuit Failure
E04
Boiler displays E04 and will not start, fan may run briefly then stop
Air Pressure Switch / Combustion Air Fault
E05
Boiler shows E05, fan runs but burner does not light
Fan Speed / Combustion Blower Fault
E06
Boiler locks out with E06, temperature reading is erratic or out of range
Supply Temperature Sensor (NTC) Fault
E07
Boiler displays E07, return temperature reading is invalid
Return Temperature Sensor (NTC) Fault
E08
Boiler shows E08, domestic hot water (DHW) temperature reading is incorrect or missing
DHW Temperature Sensor Fault
E09
Boiler locks out with E09, high limit temperature exceeded
High Limit Overheat Trip
E10
Boiler shows E10, low water pressure or lack of water in system
Low Water Pressure / Low Water Cutoff
E11
Boiler displays E11, flue gas temperature too high
Flue Gas Overtemperature
E12
Boiler shows E12, communication error between display and main control
Control Board Communication Fault
E13
Boiler displays E13, outdoor temperature sensor reading is invalid
Outdoor Sensor Fault
E14
Boiler shows E14, domestic hot water flow is detected but burner does not modulate correctly
DHW Flow Sensor / Flow Switch Fault
E15
Boiler locks out with E15, condensate system fault detected
Condensate Drain Blockage
E16
Boiler shows E16, gas valve or gas train fault
Gas Valve Control Error
E17
Boiler displays E17, internal pump or primary circulator fault
Internal Circulator Pump Failure
E18
Boiler shows E18, flame present when there should be no flame
False Flame Detection
E19
Boiler displays E19, supply/return temperature difference too high
Delta-T Too High / Flow Insufficient
E20
Boiler shows E20, supply/return temperature difference too low
Delta-T Too Low / Excessive Flow or Sensor Error
Symptom
Boiler cabinet is very hot to the touch, insulation may smell or discolor
Overheating Cabinet / Insulation Issue
Symptom
Boiler cycles on and off rapidly when only a small zone is calling for heat
Micro-Zoning / Minimum Firing Rate Mismatch
Symptom
Boiler display is blank, no lights or response from controls
No Power to Boiler
Symptom
Boiler display is on but unresponsive, buttons do not change settings
User Interface / Keypad Failure
Symptom
Boiler emits a strong exhaust or burning smell near the unit
Combustion / Venting Odor Issue
Symptom
Boiler fan runs continuously even when there is no call for heat
Fan Stuck On / Post-Purge Control Issue
Symptom
Boiler frequently locks out during very cold weather but runs fine in mild temperatures
Cold Weather Performance / Intake or Condensate Issue
Symptom
Boiler frequently releases water from the pressure relief valve
Overpressure / Expansion Problem
Symptom
Boiler ignites with a loud boom or puff back
Delayed Ignition
Symptom
Boiler leaking water from bottom of cabinet
Internal Water Leak
Symptom
Boiler makes loud banging or knocking noises when starting or stopping
Kettling / Water Hammer in Hydronic System
Symptom
Boiler runs but house does not reach set temperature, radiators lukewarm
Insufficient Heat Output
Symptom
Boiler runs but makes a high-pitched whine from the fan area
Combustion Fan Bearing or Airflow Noise
Symptom
Boiler short cycles, turning on and off frequently without maintaining steady operation
Short Cycling / Control or Sizing Issue
Symptom
Domestic hot water temperature fluctuates, alternating between hot and cold
Inconsistent DHW Temperature
Symptom
No domestic hot water, but space heating works normally
DHW Priority / Diverter Fault
Symptom
No heat to radiators or underfloor loops, but boiler appears to run
No Space Heating Circulation
Advertisements