Code 02
Water heater shuts down shortly after ignition attempt; display shows Code 02
Flame Failure / Flame Loss
Code 03
Water heater stops during operation and displays Code 03; unit may restart after some time
Power Interruption During Operation
Code 05
Water heater shuts down and displays Code 05; unit may feel very hot to the touch around the heat exchanger area
Air Intake or Exhaust Blockage / Overheat
Code 07
Unit attempts to start but shuts down with Code 07; no sustained flame
Ignition Failure
Code 10
Water heater displays Code 10 and will not operate; often after installation or vent changes
Air Supply or Exhaust Blockage / Improper Venting
Code 11
Unit will not ignite; display shows Code 11 shortly after a demand for hot water
No Ignition / Ignition Failure
Code 12
Burner lights briefly then shuts off; display shows Code 12 (flame failure during operation)
Flame Failure During Operation
Code 14
Unit shuts down with Code 14; outer case may feel warm and fan may run after shutdown
Thermal Fuse / Overheat Cutoff Activation
Code 16
Unit shuts down during long hot water use and displays Code 16 (over-temperature warning)
Outlet Water Over-Temperature
Code 19
Intermittent shutdowns with Code 19; unit may restart after cycling power
Electrical Grounding / Power Supply Error
Code 25
Unit shuts down and displays Code 25; may be accompanied by a fuel smell or abnormal combustion noise
Condensate or Drain Blockage / Abnormal Combustion
Code 29
Unit displays Code 29 and may shut down during operation, especially in cold weather
Condensate Drain Blockage / Neutralizer Issue (Condensing Models)
Code 31
Unit will not operate and displays Code 31
Inlet Thermistor Fault
Code 32
Unit displays Code 32 and will not run
Outlet Thermistor Fault
Code 33
Unit displays Code 33 and shuts down
Heat Exchanger Thermistor Fault
Code 34
Unit displays Code 34; may occur during windy conditions or vent issues
Combustion Air / Flue Thermistor Fault
Code 35
Unit displays Code 35 and will not operate
Improper Thermistor Connection / Thermistor Circuit Error
Code 41
Unit displays Code 41 and will not start
Flow Sensor Fault
Code 51
Unit displays Code 51 and will not operate
Gas Control Valve Fault
Code 52
Unit displays Code 52; ignition may be erratic
Modulating Gas Valve Signal Fault
Code 61
Unit displays Code 61 and fan may not run or runs erratically
Combustion Fan Motor Fault
Code 65
Unit displays Code 65 and may not respond correctly to water flow changes
Water Control Valve Fault
Code 71
Unit displays Code 71 and will not operate
Solenoid Valve Circuit Fault
Code 72
Unit displays Code 72; ignition may start but flame sensing is unreliable
Flame Sensing Circuit Fault
Code 73
Unit displays Code 73 and will not operate
Communication Error Between Components / Parameter Setting Error
Code 79
Unit displays Code 79 and shuts down
Fan Motor or Fan Speed Feedback Fault
Code 90
Unit displays Code 90; may be associated with poor combustion or sooting
Abnormal Combustion / Combustion Performance Error
Code 92
Unit displays Code 92 and may not modulate correctly
Combustion Fan Speed / Feedback Error
Code 99
Unit displays Code 99 and shuts down; may be intermittent
Flame Loss / Flame Detection Error
Symptom
Condensate water dripping from vent joints or around the unit
Condensate Leakage from Venting
Symptom
Exhaust smell or suspected carbon monoxide near the unit or in the home
Flue Gas Spillage / Venting Failure
Symptom
No hot water at any fixture; unit does not attempt to start (no fan or ignition sound)
No Power / Control Circuit Inactive
Symptom
No hot water at some fixtures but other fixtures get hot water normally
Plumbing Crossover or Local Mixing Issue
Symptom
Remote controller does not power on or display is blank, but unit has power
Remote Controller Power / Communication Failure
Symptom
Remote controller shows power but cannot change temperature or turn unit on/off
Remote Controller Input / Lockout
Symptom
Strong gas smell near the water heater, with or without operation
Gas Leak / Combustible Gas Odor
Symptom
Unit cycles on and off rapidly when a small amount of hot water is used (e.g., handwashing)
Short Cycling at Low Flow
Symptom
Unit freezes or is damaged after cold weather; no water flow or visible cracks
Freeze Damage / Frozen Heat Exchanger
Symptom
Unit is very noisy; loud fan or vibration sounds when running
Excessive Vibration / Fan Noise
Symptom
Unit shuts off when multiple fixtures are used; hot water stops unexpectedly under high demand
Overload / Capacity Exceeded
Symptom
Water heater is leaking from the pressure relief valve discharge pipe
Relief Valve Discharge / Overpressure
Symptom
Water heater is leaking water from the bottom of the unit
Internal Water Leak
Symptom
Water heater makes loud banging or popping noises during operation
Scale Buildup / Combustion Noise
Symptom
Water is warm but not hot enough, even with temperature set high on the controller
Insufficient Heating / Under-Temperature
Symptom
Water temperature fluctuates between hot and cold during a shower
Temperature Fluctuation / Hunting